• English
    • Deutsch
    • French
    • Requires WPML plugin
  • Country
    • United States (USD)
    • Deutschland (EUR)
    • Japan (JPY)
FREE SHIPPING FOR ALL ORDERS OF $150
0 items / $0.00
Login / Register
  • Newsletter
  • Contact Us
  • FAQs
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Vietnamese
Menu
Home Industrial Machines & Automation System Control panel cooling unit – ENC-G1310EXE
Control panel cooling unit - ENC-G820EXE
Back to products
Keithley DMM6500 6.5 Digit Multimeter with Graphical Touchscreen
Click to enlarge
Apiste

Control panel cooling unit – ENC-G1310EXE

Brand

Apiste

Application

Controller for Cooling Unit

Sub Categories

Industrial cooling, cleaning systems

Category: Industrial Machines & Automation System
Share:
close
YOU MAY ALSO LIKE…
  • FM-2031 Nitrogen Heavy Duty Soldering System Kit
  • PRESTO 981 Gun-Style Soldering Iron
  • Hakko BLUE 508 Soldering Iron
  • Soldering System with Air Control Unit
  • Description
Description

Specifications

(50/60Hz)

Mounting typeTop-mounting
Cooling capacity(W)1150/1300
Setting Temperature Range(℃)25~45
Use Area Temperature(℃)20~50
Use Area Humidity(%RH)10~85 (No condensation)
External dimensions(mm)H448×W710×D370
Weight(kg)44
Coating ColorMunsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V)Single-phase AC100
Consumption Current: Rated(A)7.2/7.0
Consumption Current: MAX(A)8.7/9.5
Starting Current(A)22.3/20.5
Consumption wattage: Rated(W)590/680
Consumption wattage: MAX(W)770/900
Noise ResistanceLEVEL4 by Fast Transient / Burst Immunity Test
Vibration ResistanceEquivalent to JIS Z 0200 Level1
Dust prevention / dust proof protection classEquivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g)R407C 385g
Noise (dB (A))Approx. 65/68
External OutputAlarm output (No-voltage/normal open: resistive load 250V 2A)
DisplayInternal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
This model can be provided with rust-proof coating specifications (optional).
For more information, please contact our sales representative.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Allowable ambient temperature: When used continuously at a low ambient temperature (15 to 20 °C or less), be sure to turn off the power supply as there is a possibility the compressor may operate at a high load.
Non-draining function operating range: At an ambient temperature/panel internal temperature of 35 °C or less and an ambient humidity/panel internal humidity of 85% or less.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit4 (M6×L12)
Drain hose3
L-shaped angles2
Insulation lock ties6
Washer2
Air direcrion louver1
Mounting nut2 (M4), 4 (M6)
Instruction manual1

Replacement parts list

Condenser side FanCirculating fan for G1310EXE
Evaporator side FanOutside air fan for G1310EXE
FilterENC-F-44
Evaporization filterVaporization filter for G1310EXE
Control PCBSubstrate for G1310EXE

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

Diagram of Panel Cutout

ENC-G1310EXE Diagram of Panel Cutout

(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m

Diagram of Panel Cutout

ENC-G1310EXE Diagram of Panel Cutout

*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.

Related products

Steering Roller System ELSWING

DV (Distributing Valve)

Segmented Roller Guider System ELSMART

Grinder Polishers – AutoMet 250

Grinder Polishers – AutoMet 300 Pro

LV (Distributing Valve for Dual Line)

Pivoting Frame System Eltrac

Abrasive Cutters – AbrasiMet™ XL Pro

CONTACT US

Hanoi Office:
Address: 5th Floor, 84 Duy Tan Street, Cau Giay District., Hanoi, Vietnam
Tel: +84 (24) 3795 9933
Fax: +84 (24) 3795 9944
Hotline: 0907910088
Email: Sales@technovietnam.com

HCM Office:
Address: No. 54, Street 6, Trung Son Area (KDC Trung Sơn), Binh Hung, Binh Chanh District, HCM
Tel: +84 (28) 5431 6377
Fax: +84 (28) 5431 6378
Hotline: 0907910088
Email: Sales@technovietnam.com

MAIN MENU

  • Home
  • About Us
  • Products
  • Partners
  • Services
  • News
  • Recruit
  • Contact Us

PRODUCT CATEGORIES

  • Reliability & Durability Test and Measurement
  • Electric & Electronic Test and Measurements
  • Industrial Machines & Automation System
  • Material Inspection and Analysis
  • Optical & Mechanical Test and Measurements
  • Other Test and Measuring Instruments
  • Parts Accessories & Consumables
  • Tools - Handtools - Industrial Tools
COPYRIGHT 2015 TECHNO VIETNAM. ALL RIGHTS RESERVED.
payments
Close
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Shopping cart
close

Sign in

close

Lost your password?

No account yet?

Create an Account
Sidebar
Start typing to see products you are looking for.
x
x
Home
Shop
Blog
Menu