Specifications
(50/60Hz)
Mounting type | Side-mounting |
---|---|
Cooling capacity(W) | 900/1000 |
Setting Temperature Range(℃) | 25~45 |
Use Area Temperature(℃) | 20~50 |
Use Area Humidity(%RH) | 10~85 (No condensation) |
External dimensions(mm) | H850×W350×D230 |
Weight(kg) | 29 |
Coating Color | Munsell 5Y 7/1 Equivalent color of light beige |
Rated Voltage(V) | Single-phase AC200 |
Consumption Current: Rated(A) | 2.8/2.5 |
Consumption Current: MAX(A) | 3.2/3.1 |
Starting Current(A) | 9.1/8.7 |
Consumption wattage: Rated(W) | 460/480 |
Consumption wattage: MAX(W) | 565/595 |
Noise Resistance | LEVEL4 by Fast Transient / Burst Immunity Test |
Vibration Resistance | 5Hz frequency 20mm total amplitude |
Dust prevention / dust proof protection class | Equivalent to IP54 (internal circulation route) |
Refrigerant / Fill ration(g) | R134a 280g |
Noise (dB (A)) | Approx. 74/76 |
External Output | Alarm output (No-voltage/normal open: resistive load 250V 2A) |
Display | Internal temperature/Error display LED/RUN LED |
Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal temperature is 35°C. (measurement conditions: JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : use area temperature 35°C , use area humidity RH 40%.
MAX value: Value at the maximum ambient temperature allowed and an operating ambient humidity of 40%RH.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.
Accessories list
Mounting bolt for main unit | 6 (M6×L20) |
---|---|
Drain hose | 5m |
Insulation lock ties | 1 |
Spacer | 6 (6.5×5.5L) |
Instruction manual | 1 |
Replacement parts list
Condenser side Fan | Circulating fan for A1020L-DF |
---|---|
Evaporator side Fan | Outside air fan for A1020L-DF |
Filter | ENC-F-51 (2 pieces) |
Control PCB | Substrate for A1020L-DF |
Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.
External dimensions
(1) Power line : Cord length 3m
(2) Cooling operation output Line : Cord length 3m
(3) Alarm Output Line : Cord length 3m
Diagram of Panel Cutout
[Standard panel cut]*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.