Control panel cooling unit – ENC-A3500EX

Thương hiệu : Apiste

Cam kết và Chính sách của TECHNO

  • icon

    Cam kết 100% Hàng chính hãng

  • icon

    Chất lượng cao, đáp ứng đa dạng nhu cầu

  • icon

    Tư vấn kỹ thuật toàn diện và chuyên sâu

  • icon

    Chính sách bảo hành và hỗ trợ nhanh chóng

Specifications

(50/60Hz)

Mounting type Top-mounting
Cooling capacity(W) 3200/3500
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 25~55
Use Area Humidity(%RH) 10~80 (No condensation)
External dimensions(mm) H500×W1000×D550
Weight(kg) 76
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Single-phase AC200
Consumption Current: Rated(A) 7.8/8.0
Consumption Current: MAX(A) 9.5/9.8
Starting Current(A) 33/30
Consumption wattage: Rated(W) 1350/1600
Consumption wattage: MAX(W) 1750/2000
Noise Resistance LEVEL4 by Fast Transient / Burst Immunity Test
Vibration Resistance 5Hz frequency 20mm total amplitude
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R134a 740g
Noise (dB (A)) Approx. 73/76
External Output Cooling operation output/Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal temperature is 35°C. (measurement conditions: JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : use area temperature 35°C , use area humidity RH 40%.
MAX value: Value at the maximum ambient temperature allowed and an operating ambient humidity of 40%RH.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 6 (M8×L25)
Drain hose 3m
L-shaped angles 2
Insulation lock ties 6
Washer 2
Air direcrion louver 1
Eyebolt 4 (M10)
Mounting nut 6 (M8)
Instruction manual 1

Replacement parts list

Condenser side Fan Circulating fan for A3500EX
Evaporator side Fan Outside air fan for A3500EX
Filter ENC-F-40(2 pieces)
Control PCB Substrate for A3500EX

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

External dimensions

ENC-A3500EX External dimensions

(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m
(3) RUN output Line : Cord length 3m
(4) Thermistor