Specifications
(50/60Hz)
| Mounting type | Top-mounting |
|---|---|
| Cooling capacity(W) | 3200/3500 |
| Setting Temperature Range(℃) | 25~45 |
| Use Area Temperature(℃) | 25~55 |
| Use Area Humidity(%RH) | 10~80 (No condensation) |
| External dimensions(mm) | H500×W1000×D550 |
| Weight(kg) | 76 |
| Coating Color | Munsell 5Y 7/1 Equivalent color of light beige |
| Rated Voltage(V) | Single-phase AC200 |
| Consumption Current: Rated(A) | 7.8/8.0 |
| Consumption Current: MAX(A) | 9.5/9.8 |
| Starting Current(A) | 33/30 |
| Consumption wattage: Rated(W) | 1350/1600 |
| Consumption wattage: MAX(W) | 1750/2000 |
| Noise Resistance | LEVEL4 by Fast Transient / Burst Immunity Test |
| Vibration Resistance | 5Hz frequency 20mm total amplitude |
| Dust prevention / dust proof protection class | Equivalent to IP54 (internal circulation route) |
| Refrigerant / Fill ration(g) | R134a 740g |
| Noise (dB (A)) | Approx. 73/76 |
| External Output | Cooling operation output/Alarm output (No-voltage/normal open: resistive load 250V 2A) |
| Display | Internal temperature/Error display LED/RUN LED |
Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal temperature is 35°C. (measurement conditions: JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : use area temperature 35°C , use area humidity RH 40%.
MAX value: Value at the maximum ambient temperature allowed and an operating ambient humidity of 40%RH.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.
Accessories list
| Mounting bolt for main unit | 6 (M8×L25) |
|---|---|
| Drain hose | 3m |
| L-shaped angles | 2 |
| Insulation lock ties | 6 |
| Washer | 2 |
| Air direcrion louver | 1 |
| Eyebolt | 4 (M10) |
| Mounting nut | 6 (M8) |
| Instruction manual | 1 |
Replacement parts list
| Condenser side Fan | Circulating fan for A3500EX |
|---|---|
| Evaporator side Fan | Outside air fan for A3500EX |
| Filter | ENC-F-40(2 pieces) |
| Control PCB | Substrate for A3500EX |
Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.
External dimensions

(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m
(3) RUN output Line : Cord length 3m
(4) Thermistor
Diagram of Panel Cutout