Specifications
(50/60Hz)
Mounting type | Top-mounting |
---|---|
Cooling capacity(W) | 950/1100 |
Setting Temperature Range(℃) | 25~45 |
Use Area Temperature(℃) | 20~50 |
Use Area Humidity(%RH) | 10~85 (No condensation) |
External dimensions(mm) | H318×W600×D353 |
Weight(kg) | 28 |
Coating Color | NSSC 180-HL Finish |
Rated Voltage(V) | Single-phase AC200 |
Consumption Current: Rated(A) | 2.7/2.4 |
Consumption Current: MAX(A) | 3.2/3.3 |
Starting Current(A) | 7.5/7.1 |
Consumption wattage: Rated(W) | 440/470 |
Consumption wattage: MAX(W) | 570/630 |
Noise Resistance | LEVEL4 by Fast Transient / Burst Immunity Test |
Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
Dust prevention / dust proof protection class | Equivalent to IP54 (internal circulation route) |
Refrigerant / Fill ration(g) | R134a 240g |
Noise (dB (A)) | Approx. 60/65 |
External Output | Cooling operation output/Alarm output (No-voltage/normal open: resistive load 250V 2A) |
Display | Internal temperature/LED/RUN LED |
Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Use area temperature: If the outside air temperature is 0 ° C or lower, set the temperature internal to 30 ° C or higher.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.
Accessories list
Hexagon bolt with flange | 4 (M6×12) |
---|---|
Nut with a flange | 4 (M6) |
Drain hose | 3m |
L-shaped angles | 2 |
Insulation lock ties | 6 |
Washer | 2(M6) |
Air direcrion louver | 1 |
Mounting nut | 2(M4)(For louver mounting) |
Instruction manual | 1 |
Replacement parts list
Condenser side Fan | Circulating fan for AR1120EX-SUS-2 |
---|---|
Evaporator side Fan | Circulating fan for AR1120EX-SUS-2 |
Filter | ENC-F-21 |
Control PCB | Substrate for AR1120EX-SUS-2 |
Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.
External dimensions
NC-AR1120EX-SUS-2
(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m
Diagram of Panel Cutout
ENC-AR1120EX-SUS-2[Standard Panel Cut (Top)]*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply).
*The power cable retrieval section is either slanted or machined to a diameter or φ50.