Specifications

(50/60Hz)

Mounting type Side-mounting
Cooling capacity(W) 300/350
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 20~50
Use Area Humidity(%RH) 10~85 (No condensation)
External dimensions(mm) H280×W450×D150
Weight(kg) 14
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Single-phase AC200
Consumption Current: Rated(A) 1.8/1.4
Consumption Current: MAX(A) 2.0/1.8
Starting Current(A) 4.0/4.2
Consumption wattage: Rated(W) 280/260
Consumption wattage: MAX(W) 350/340
Vibration Resistance Equivalent to JIS Z 0200 Level1
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R134a 80g
Noise (dB (A)) Approx. 60/63
External Output Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 4 (M6×L20)
Drain hose 2m
Insulation lock ties 1
Spacer 4
Instruction manual 1

Replacement parts list

Condenser side Fan Circulating fan for G352WL
Evaporator side Fan Outside air fan for G352WL
Filter ENC-F-32 (2 pieces)
Control PCB Substrate for G352WL

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

External dimensions

ENC-G352WL External dimensions

Diagram of Panel Cutout

ENC-G352WL Diagram of Panel Cutout

[Standard panel cut]
*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.