Specifications

(50/60Hz)

Mounting type Top-mounting
Cooling capacity(W) 1150/1300
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 20~50
Use Area Humidity(%RH) 10~85 (No condensation)
External dimensions(mm) H448×W710×D370
Weight(kg) 44
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Single-phase AC100
Consumption Current: Rated(A) 7.2/7.0
Consumption Current: MAX(A) 8.7/9.5
Starting Current(A) 22.3/20.5
Consumption wattage: Rated(W) 590/680
Consumption wattage: MAX(W) 770/900
Noise Resistance LEVEL4 by Fast Transient / Burst Immunity Test
Vibration Resistance Equivalent to JIS Z 0200 Level1
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R407C 385g
Noise (dB (A)) Approx. 65/68
External Output Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
This model can be provided with rust-proof coating specifications (optional).
For more information, please contact our sales representative.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Allowable ambient temperature: When used continuously at a low ambient temperature (15 to 20 °C or less), be sure to turn off the power supply as there is a possibility the compressor may operate at a high load.
Non-draining function operating range: At an ambient temperature/panel internal temperature of 35 °C or less and an ambient humidity/panel internal humidity of 85% or less.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 4 (M6×L12)
Drain hose 3
L-shaped angles 2
Insulation lock ties 6
Washer 2
Air direcrion louver 1
Mounting nut 2 (M4), 4 (M6)
Instruction manual 1

Replacement parts list

Condenser side Fan Circulating fan for G1310EXE
Evaporator side Fan Outside air fan for G1310EXE
Filter ENC-F-44
Evaporization filter Vaporization filter for G1310EXE
Control PCB Substrate for G1310EXE

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

Diagram of Panel Cutout

ENC-G1310EXE Diagram of Panel Cutout

(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m

Diagram of Panel Cutout

ENC-G1310EXE Diagram of Panel Cutout

*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.