Product Summary
RCF-free (alumina fiber) that complies with RCF regulations is used for the furnace chamber.
Features of Standard Electric Furnace (FO101)
- Features
- RCF-free, safe and secure
- Features
- Simple Operation
- Features
- Equipped with program operation and timer function
- Features
- Improved safety functions
- Features
- Uses R thermocouple
- Features
- Equipped with a variety of options
Specifications
Specifications
Item Code | 214136 |
---|---|
Model | FO101 |
Operating temp. range | 100 to 1,150℃ |
Temp. control accuracy | ±2.0℃(at 1,150℃) |
Max. temp. reaching time | Approx. 60min. |
Exterior material | Chrome-free electro-galvanized steel plate, Chemical proof painting |
Internal material | Alumina fiber |
Sensor | R-thermocouple |
Heater | Iron-chrome wire |
Heater | 1kW |
Exhaust port | 20 mm I.D. (upper part) |
Cooling Fan Type | Axial fan motor |
Temp. controller | PID control by microprocessor |
Temp. setting/display method | Digital setting by▲/▼ keys / Digital display |
Overheat protection | Integrated controller |
Overheat protection set | Digital setting |
Operation function | Fixed temp., program (6 modes 30 seg.×1, 15 seg.×2, 10 seg.×3) |
Additional function | Calibration off-set, Power outage compensation |
Timer | 1min to 99hr59min and 999hr 50min digital setting, Auto start, Quick auto stop |
Safe Device | Self diagnosis circuit (Abnormal temp. sensor, Auto overheat protection), Averheat protector, Avercurrent ELB |
Accessories | 1 exhaust cap, 1 thermal fuse |
Internal dimensions(W×D×H mm) | 100×150×105mm |
External dimensions(W×D×H mm) | 346×405×517mm |
Remarks(dimensions) | 1.5L |
Power Source | Single Phase AC100V 11A Plug is not attached, Electric code length is 2m |
Weight | 24kg |
Maintenance and warranty
Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.