Measurement Range:K -200 to 1370°C / E -200 to 800°C
The thermometer stops measurement
by the HOLD key and holds the present readings.
The thermometer will turn the power off automatically after 5minutes.
Press the [RESO] key to change the resolution of readings.
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Stores readings at user-selected time intervals.
User specified time interval and the remaining amount of memory are displayed on the sub-display.
(Temperature probes not included)
Specifications
Model | HR-1500 | ||
Display | LCD | ||
Waterproof specifications | – | ||
Input connector | ASP | ||
Input type | Thermocouple Input: Type E, K | ||
Channel | 1ch | ||
Signal source resistance | MAX.1k ohm | ||
Measurement Range | 1°C Resolution | E | -200 to 800°C |
K | -200 to 1370°C | ||
0.1°C Resolution | E | -104.9 to 504.9°C
(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) |
|
K | -104.9 to 504.9°C
(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) |
||
Measurement Accuracy | 1°C Resolution | 0°C to | ± (0.1% of reading +1°C) |
to 0°C | ± (0.5% of reading +1°C) | ||
0.1°C Resolution | 0°C to | ± (0.05% of reading + 0.2°C) | |
to 0°C | ± (0.15% of reading + 0.2°C) | ||
Reference junction compensation accuracy | ±0.2°C at 25°C±10°C | ||
Temperature Coefficient*1 | ±0.02×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.3°C is added at room temp. of 0°C or 50°C) | ||
Operation Environment | 0 to 50°C, 0 to 80%RH (Non condensing) | ||
Storage Environment | -20 to 50°C, 0 to 85%RH (Non condensing) | ||
Battery life | approx.550h | ||
Power supply(Dry battery) | 4 AA Alkaline batteries | ||
Power supply(AC power) option | available | ||
Sampling rate | approx.200ms | ||
Linearlizer | Digital Linearizer method (Compliant with JIS C1602-2015) | ||
Dimensions(mm) | approx. 82(w)×166(H)×36(D) [Protruded parts excluded] | ||
Weight | approx. 350g [Include Batteries] | ||
Supplied accessories | Manual,Test report,Soft case, | ||
Hand strap,4 AA Alkaline batteries | |||
Optional accessories | Communication cable, Software(AMS-350) | ||
Memory function | TABLE1 | ||
Compatible standards | EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)
RoHS:IEC EN 63000:2018 |
*1 Only when the temp. exceeds 25°C±10°C
※ Details of typeJ,T,R(option)
TABLE1 Memory function
Time interval | second:1, 5, 10, 30 minutes:1, 5, 10, 30, 60 and manual memory |
Memory capacity | 19999data |
Software
Download data
Data stored in memory can be transmitted to a personal computer through USB interface and can converted into CSV files.
Operational environment OS software(AMS-350)
OS | Windows® 8.1、Windows® 10 |
System | 32bit / 64bit |
* All PCs under the recommended environment are not guaranteed to work successfully with AMS-950.
* AMS-950 can be used only by the user that has a system administrative right (Administrator)
* Microsoft® Windows® 8.1, Windows® 10, and Excel® are registered trademarks of Microsoft Corporation in the United States and other countries.