Measurement Range:K -200 to 1370°C / E -200 to 800°C
The thermometer stops measurement
by the HOLD key and holds the present readings.
The thermometer will turn the power off automatically after 5minutes.
Press the [RESO] key to change the resolution of readings.
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
The displayed value can be adjusted the CAL SET key.
The thermometer gives an alarm when readings go beyond the high or low limits.
(Temperature probes not included)
Specifications
Model | HR-1300 | ||
Display | LCD | ||
Waterproof specifications | – | ||
Input connector | ASP | ||
Input type | Thermocouple Input: Type E, K | ||
Channel | 1ch | ||
Signal source resistance | MAX.1k ohm | ||
Measurement Range | 1°C Resolution | E | -200 to 800°C |
K | -200 to 1370°C | ||
0.1°C Resolution | E | -104.9 to 504.9°C
(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) |
|
K | -104.9 to 504.9°C
(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) |
||
Measurement Accuracy | 1°C Resolution | 0°C to | ± (0.1% of reading +1°C) |
to 0°C | ± (0.5% of reading +1°C) | ||
0.1°C Resolution | 0°C to | ± (0.05% of reading + 0.2°C) | |
to 0°C | ± (0.15% of reading + 0.2°C) | ||
Reference junction compensation accuracy | ±0.2°C at 25°C±10°C | ||
Temperature Coefficient*1 | ±0.02×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.3°C is added at room temp. of 0°C or 50°C) | ||
Operation Environment | 0 to 50°C, 0 to 80%RH (Non condensing) | ||
Storage Environment | -20 to 50°C, 0 to 85%RH (Non condensing) | ||
Battery life | approx.600h | ||
Power supply(Dry battery) | 4 AA Alkaline batteries | ||
Power supply(AC power) option | available | ||
Sampling rate | approx.200ms | ||
Linearlizer | Digital Linearizer method (Compliant with JIS C1602-2015) | ||
Dimensions(mm) | approx. 82(w)×166(H)×36(D) [Protruded parts excluded] | ||
Weight | approx. 350g [Include Batteries] | ||
Supplied accessories | Manual,Test report,Soft case, | ||
Hand strap,4 AA Alkaline batteries | |||
Optional accessories | Alarm output cable | ||
Alarm output | TABLE1 | ||
Compatible standards | EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)
RoHS:IEC EN 63000:2018 |
*1 Only when the temp. exceeds 25°C±10°C
※ Details of typeJ,T,R(option)
Table1 Alarm output
Output Pattern | Upper Limit | Lower Limit |
More than upper limit | Close | Open |
Between upper and lower limit | Open | Open |
Less than lower limit | Open | Close |
Alarm output cable | ANGHA-1.5(accessory) |
※ The alarm output uses a photo MOS relay. ON resistance (internal protection resistance 400Ω, photo MOS relay ON resistance 50Ω) Drive voltage MAX.25V