The F90 Series is a panel mounted Rate Indicator/Controller. It has a 6-digit red LED display, 14.22×7.8mm digit size, easy to see measured value even at dimly lit places. The Controller type is fully programmable thru the front panel keys. Panel size is a DIN 48×96 with a Panel Cut-out size of 45x92mm. Controller model has 3 output types – Upper/Lower Limit output, Analog and BCD output. Other features include Prescale function, multi-decimal point position and Key Lock function. Built-in memory enables the unit to remember the last measured value even at accidental cut of power supply.
Model | F90-101 | F90-103 | F90-201 | F90-203 |
Type | MONITOR TYPE | UPPER / LOWER LIMIT PRESET TYPE | ||
Output Option | – | Analog | – | Analog |
Display | Red LED 14.22 x 7.8mm | Measuring Display : Red LED 10.5 x 5.5mm Preset Display : Green LED 8.0 x 4.0 mm |
||
Number of Digits | 6 | |||
Display Range | 0.0001 – 999999 | |||
Decimal Point Position | 4th decimal point position max. | |||
Scale Range | 0.11 – 20KHz (1pulse / revolution : 6.6667 – 120000rpm) | |||
Preset Level | – | Upper / Lower Limit | ||
Measuring Method | 1/TAU standard sampling : X’tal 2MHz ±50ppm | |||
Measuring Accuracy | ±0.008% reading ±1 digit (multiplier = 1.0000, divider = 1, -5 – +50°C ) | |||
Sampling Time | 0.5 – 10 seconds (sampling time is changed automatically by pulse interval) | |||
Up-date Time | Every sampling or 1 – 99seconds (maximum) | |||
Input Signal | Contact inpu t: sink current 2mA Open collector input sink current : 2mA L : 0 – 1.9V Voltage input : input impedance 3KΩ L : 0 – 1.9V H : 3.5 – 30V (P-P3.5V min.) Magnetic sensor input : input impedance 3KΩ L : -0.6 – -17V H : 0.6 – 17V |
|||
Input Frequency | Contact input 0.11 – 25Hz minimum pulse width 20msec Open collector or Voltage input 0.11H – 20KHz minimum pulse width 25msec Magnetic sensor inpu 0.11 – 20KHz minimum pulse width 25msec (L : -0.6Vmax. / H : 0.6Vmin) |
|||
Prescale | Multiplier : 0.0001 – 100 Divider : 1/1 – 1/9999 (can be used at the same time) | |||
Overflow | At every sampling, when the measured data is over 6 digits, “—–” is displayed | |||
Memory | Prescale value, upper/lower limit value and up date time are retained for 10 yrs. by E²PROM (rewrite 10000 times) |
|||
Keylock | Prescale value, upper/lower limit value (exclude monitor type) and up date time are inhibited to be changed. Contact input, Open collector input (sink current 7mA L : 2Vmax) |
|||
Output Inhibition | – | Upper / Lower Limit output inhibition Contact input, Open Collector input (sink current 7mA L : 2Vmax) |
||
Upper / Lower Output | – | Type 1C relay contact (AC250V/0.5A or DC30V/2A) |
||
BCD Output | Parallel open collector negative logic output Each output 30VDC/20mA/50mW max. Output saturation voltage 0.75V (typ)/20mA Half pitch 36P connector : JAE TX20A-36R-D2LT-A1L Adapter Plug : JAE TX20A-36PH1-D2P1 1m cable |
|||
Analog Output | Frequency voltage converter method Voltage Output : 0.1 – 10V (1KΩ min.) ±0.5%FS Current Output : 4.16 – 20mA (500W max.) ±0.5%FS Output Ripple : 20mVp-p max. 3 Ranges: 20 – 200Hz, 200 – 2KHz, 200 – 20KHz selectable by dip-switches (Select voltage or current output). |
|||
Sensor Supply Power Source |
12VDC ±10% 100mA max. (Analog output is 50mA maximum) | |||
Power Supply | 100 – 240VAC -15% +10% (85 – 264VAC) 50/60Hz | |||
Power Consumption | Approximately 6VA | |||
Operating Temperature | -5 – +50°C (Non-freezing) | |||
Operating Humidity | 45 – 85%RH (Non-condensing) | |||
Weight | Approximately 280g |