The AQ6360 optical analyzer is the fastest optical spectrum analyzer for optical device manufacturing offered by Yokogawa. It is a cost-effective optical spectrum analyzer ideal for industrial manufacturing of telecom devices such as lasers, optical transceivers, and optical amplifiers.
The AQ6360 features a wavelength range of 1200 to 1650 nm for ideal manufacturing test performance. Its free-space optical input structure design allows for guaranteed high coupling efficiency and measurement repeatability. Additional features and functions of the AQ6360 include built-in analysis functions and Ethernet and GPIB remote interfaces
Items | Specifications |
Applicable fiber | SM (9.5/125 μm), GI (50/125 μm, 62.5/125 μm) |
Wavelength range | 1200 to 1650 nm |
Span | 0.1 to 450 nm (entire wavelength range), and 0 nm |
Wavelength accuracy | ±0.02 nm (1520 to 1580 nm), ±0.04 nm (1580 to 1620 nm), ±0.10 nm (1200 to 1650 nm) |
Wavelength linearity | ±0.02 nm (1520 to 1580 nm, 1580 to 1620 nm) |
Wavelength repeatability | ±0.01 nm (1 min.) |
Wavelength resolution setting | 0.1, 0.2, 0.5, 1 and 2 nm |
Wavelength resolution bandwidth accuracy | ±5% |
Minimum sampling resolution | 0.001 nm |
Number of sampling points | 101 to 50001, AUTO |
Level sensitivity setting | NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, and HIGH2 |
Level sensitivity | -80 dBm (1300 to 1620 nm, sensitivity: HIGH2, resolution: 0.1 nm) |
Maximum input power | +20 dBm (Input power per set wavelength resolution) |
Maximum safe input power | +25 dBm (Total input power) |
Level accuracy | ±0.5 dB (1310/1550 nm, –20 dBm, sensitivity: MID, HIGH1-2) |
Level linearity | ±0.1 dB (Input level: –50 to +10 dBm, sensitivity: MID, HIGH1-2) |
Level flatness | ±0.2 dB (1520 to 1580 nm, 1580 to 1620 nm) |
Polarization dependence | ±0.1 dB (1550 nm) |
Dynamic range | 55 dB (Peak ±0.4 nm), 40 dB (Peak ±0.2 nm)(Resolution: 0.1 nm) |
Optical return loss | 35 dB (Typ., with angled-PC connector) |
Optical input connector | FC or SC |
Built-in calibration light source (option) | Wavelength reference source (For wavelength calibration) |
Sweep time | NORM_AUTO: 0.2 s, NORMAL: 0.5 s, MID: 1 s, HIGH1: 2.5 s, HIGH2: 10 s |
Warm-up time | Minimum 1 hour (After warm-up, the wavelength calibration is required.) |
Electrical interface | GP-IB, Ethernet, USB, SVGA output |
Remote control | GP-IB, Ethernet (TCP/IP), AQ6317 series compatible commands (IEEE488.1) and IEEE488.2 |
Data storage | Internal storage: 512 MBytes, external storage: USB storage (memory/HDD), file types: CSV (text), Binary, BMP, TIFF |
Display | 8.4-inch color LCD (Touchscreen, resolution: 800 × 600 pixels) |
Dimensions and weight | Approx. 426 (W) × 177 (H) × 459 (D) mm (excluding protector and handle), Approx. 15.5 kg |
Power requirements | 100 to 240 V AC, 50/60 Hz, approx. 100 VA |
Environmental conditions | Performance guarantee temperature: +18 to +28°C, Operating temperature: +5 to +35°C, Storage temperature: .10 to +50°C, Humidity: 20 to 80%RH (no condensation) |
Safety standards | EN 61010-1 |
Laser: EN 60825-1: 2014, IEC 60825-1: 2007, GB 7247.1-2012 Class 1 |