• English
    • Deutsch
    • French
    • Requires WPML plugin
  • Country
    • United States (USD)
    • Deutschland (EUR)
    • Japan (JPY)
FREE SHIPPING FOR ALL ORDERS OF $150
0 items / $0.00
Login / Register
  • Newsletter
  • Contact Us
  • FAQs
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Vietnamese
Menu
Home Test and Measurements GENRAD 1403 SERIES HIGH FREQUENCY STANDARD CAPACITOR
GENRAD 1409 SERIES STANDARD CAPACITOR
Back to products
GENRAD 1422 SERIES VARIABLE AIR CAPACITORS
Click to enlarge
IET Labs, Inc

GENRAD 1403 SERIES HIGH FREQUENCY STANDARD CAPACITOR

Brand

IET Labs, Inc

Sub Categories

Lab tools

Application

Standard Capacitor

Category: Test and Measurements
Share:
close
YOU MAY ALSO LIKE…
  • No.1840-00 Min-Max Digital Thermometer PC-3510
  • No.1830-00 Refrigerator Digital Thermometer PC-3310
  • No.1758-00 Waterproof Digital Thermometer PC-9235
  • No. 1756-00 waterproof digital thermometer PC-9230
  • GENERAL
  • DESCRIPTION
  • SPECIFICATION
  • DATASHEET AND MANUAL
  • APPLICATION NOTES AND SOFTWARE
  • ACCESSORIES
GENERAL

GENERAL

    • Available in values from 0.001 pF – 1000 pF
    • Excellent performance at high frequencies
    • ISO-17025 accredited calibration included with the standard
    • NEW 1403-1pF-BNC and 1403-0.001pF-BNC versions
    Consult IET Labs, Inc for pricing information

 

DESCRIPTION

DESCRIPTION

GenRad 1403 Series High Frequency Standard Capacitor Basic Specifications

Calibration: A certificate of calibration is supplied with each unit giving the measured capacitance at 1 kHz and at a specified temperature.
The measured value is the direct capacitance between shielded terminals when the capacitor has at least one lead completely shielded and its case connected to a guard point.

The calibrated capacitance value is obtained by direct measurement using an AH2700A Capacitance Bridge or comparison, to a precision better than ±(0.01% + 0.00001 pF), with standards whose calibrated values are known to an accuracy < 10 ppm, and are periodically calibrated traceable to the SI through a national metrology institute (NIST, NRC, etc).

Stability: Capacitance change is less than 0.05% per year.

Temperature Coefficient of Direct Capacitance: Typically 20 to 40 ppm per degree between 20° and 70°C. The larger coefficients apply to the smaller capacitance values

Terminals: GR874 Coaxial Connectors, which provide complete shielding of the leads
Two bnc-f connectors for -BNC versions

SPECIFICATION

SPECIFICATION

GenRad 1403 Series High Frequency Standard Capacitor Basic Specifications

Calibration: A certificate of calibration is supplied with each unit giving the measured capacitance at 1 kHz and at a specified temperature.
The measured value is the direct capacitance between shielded terminals when the capacitor has at least one lead completely shielded and its case connected to a guard point.

The calibrated capacitance value is obtained by direct measurement using an AH2700A Capacitance Bridge or comparison, to a precision better than ±(0.01% + 0.00001 pF), with standards whose calibrated values are known to an accuracy < 10 ppm, and are periodically calibrated traceable to the SI through a national metrology institute (NIST, NRC, etc).

Stability: Capacitance change is less than 0.05% per year.

Temperature Coefficient of Direct Capacitance: Typically 20 to 40 ppm per degree between 20° and 70°C. The larger coefficients apply to the smaller capacitance values

Terminals: GR874 Coaxial Connectors, which provide complete shielding of the leads
Two bnc-f connectors for -BNC versions

DATASHEET AND MANUAL

DATASHEET AND MANUAL

  • Data Sheet: This document explains the features, options, Specifications and option models for this item.
  • Product Manual: Specifications and option models for this item. This document contains the technical product manual and guidelines.
APPLICATION NOTES AND SOFTWARE

APPLICATION NOTES AND SOFTWARE

  • Application Notes: Application notes and technical resources for this instrument.
ACCESSORIES

ACCESSORIES

ISO-17025 Accredited Calibration with Test Data

ISO-17025 ACCREDITED CALIBRATION WITH TEST DATA
BNC to BNC Extender Cable, 1 meter

1689-9602 BNC-BNC EXTENDER CABLE
GR874 to BNC Female Adapter

GR-874 TO BNC ADAPTER – LD-08

 

Related products

TC-Series (3-Axis Changeover Systems)

Data Acquisition Analysis System Wave Stocker (VM-0330/16)

CardVibro Air2 (VM-2012/VM-2012C)

Digital Charge-input Vibrometer (VM-1970)

Seismic Monitoring System (SW-72)

No.371-S CARDBOARD CONTAINER COMPRESSION TESTER

A-Series (High Grade Range)

Charge Amplifier (VM-1980/3)

CONTACT US

Hanoi Office:
Address: 5th Floor, 84 Duy Tan Street, Cau Giay District., Hanoi, Vietnam
Tel: +84 (24) 3795 9933
Fax: +84 (24) 3795 9944
Hotline: 0907910088
Email: Sales@technovietnam.com

HCM Office:
Address: No. 54, Street 6, Trung Son Area (KDC Trung Sơn), Binh Hung, Binh Chanh District, HCM
Tel: +84 (28) 5431 6377
Fax: +84 (28) 5431 6378
Hotline: 0907910088
Email: Sales@technovietnam.com

MAIN MENU

  • Home
  • About Us
  • Products
  • Partners
  • Services
  • News
  • Recruit
  • Contact Us

PRODUCT CATEGORIES

  • Reliability & Durability Test and Measurement
  • Electric & Electronic Test and Measurements
  • Industrial Machines & Automation System
  • Material Inspection and Analysis
  • Optical & Mechanical Test and Measurements
  • Other Test and Measuring Instruments
  • Parts Accessories & Consumables
  • Tools - Handtools - Industrial Tools
COPYRIGHT 2015 TECHNO VIETNAM. ALL RIGHTS RESERVED.
payments
Close
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Shopping cart
close

Sign in

close

Lost your password?

No account yet?

Create an Account
Sidebar
Start typing to see products you are looking for.
x
x
Home
Shop
Blog
Menu