Improved working and testing efficiency
Multi-axis (switching) vibration testers are mainly used to ‘improve testing and working efficiency’.
Specifications
Standard
System Model | Unit | DC-1000-4H | DC-1000-6H | DC-1000-8H | DC-1000-10M | DC-2000-5H | DC-2000-8M | DC-2000-10M | DC-2000-15M | DC-3000-5H | DC-3000-8M | DC-3000-10M | DC-3000-15M | ||
System Specifications | Table Size | mm | □ 400 | □ 600 | □ 800 | □ 1000 | □ 500 | □ 800 | □ 1000 | □ 1500 | □ 500 | □ 800 | □ 1000 | □ 1500 | |
Rated Force | Sine | kN | 9.8 | 9.8 | 9.8 | 9.8 | 19.6 | 19.6 | 19.6 | 19.6 | 29.4 | 29.4 | 29.4 | 29.4 | |
Random | kN | 4.9 | 4.9 | 4.9 | 4.9 | 9.8 | 9.8 | 9.8 | 9.8 | 14.7 | 14.7 | 14.7 | 14.7 | ||
Shock | kN | 14.7 | 14.7 | 14.7 | 14.7 | 29.4 | 29.4 | 29.4 | 29.4 | 44.1 | 44.1 | 44.1 | 44.1 | ||
Maximum Acceleration | m/s² | 108 | 75 | 54 | 32 | 150 | 81 | 67 | 28 | 196 | 140 | 91 | 47 | ||
Maximum Velocity | m/s | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 0.9 | 1.0 | 1.0 | 1.0 | 0.9 | ||
Maximum Displacement | mmp-p | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | ||
Armature Mass | kg | 90 | 130 | 180 | 300 | 130 | 240 | 290 | 680 | 150 | 210 | 320 | 620 | ||
Maximum Frequency | Horizontal | Hz | 1 | 800 | 700 | 350 | 800 | 500 | 350 | 250 | 800 | 500 | 350 | 250 | |
Vertical | Hz | 1 | 1 | 700 | 500 | 800 | 800 | 500 | 350 | 800 | 800 | 500 | 350 | ||
Maximum Load | kg | 100 | 100 | 200 | 200 | 200 | 300 | 500 | 500 | 200 | 300 | 500 | 500 | ||
Power Requirements | kVA | 25 | 25 | 25 | 25 | 43 | 43 | 43 | 43 | 52 | 52 | 52 | 52 | ||
Primary Cooling Water | ℓ/min | – | – | – | – | – | – | – | – | – | – | – | – |
System Model | Unit | DC-5000-6H | DC-5000-8H | DC-5000-10M | DC-5000-15M | DC-6000-6H | DC-6000-8H | DC-6000-10M | DC-6000-15M | ||
System Specifications | Table Size | mm | □ 600 | □ 800 | □ 1000 | □ 1500 | □ 600 | □ 800 | □ 1000 | □ 1500 | |
Rated Force | Sine | kN | 49 | 49 | 49 | 49 | 61.7 | 61.7 | 61.7 | 61.7 | |
Random | kN | 29.4 | 29.4 | 24.5 | 24.5 | 37 | 37 | 30.8 | 30.8 | ||
Shock | kN | 73.5 | 73.5 | 58.8 | 58.8 | 92.5 | 92.5 | 74 | 74 | ||
Maximum Acceleration | m/s² | 350 | 204 | 163 | 59 | 385 | 268 | 102 | 75 | ||
Maximum Velocity | m/s | 1.0 | 1.0 | 0.9 | 0.9 | 1.0 | 1.0 | 0.9 | 0.9 | ||
Maximum Displacement | mmp-p | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | ||
Armature Mass | kg | 140 | 240 | 300 | 820 | 160 | 230 | 600 | 820 | ||
Maximum Frequency | Horizontal | Hz | 800 | 700 | 350 | 250 | 800 | 700 | 350 | 250 | |
Vertical | Hz | 1 | 800 | 500 | 350 | 1 | 800 | 500 | 350 | ||
Maximum Load | kg | 300 | 300 | 500 | 700 | 300 | 300 | 500 | 700 | ||
Power Requirements | kVA | 75 | 75 | 73 | 73 | 93 | 93 | 91 | 91 | ||
Primary Cooling Water | ℓ/min | 195 | 195 | 190 | 190 | 230 | 230 | 225 | 225 |
* Depending on the reference PSD or other operating conditions such as the specimen, one part of the controlled response may deviate from the reference PSD. |
* The above is just an example. Specifications may be changed depending on test conditions. Please contact us for more information. |
US:Standard
System Model | Unit | DC-1000-4H | DC-1000-6H | DC-1000-8H | DC-1000-10M | DC-2000-5H | DC-2000-8M | DC-2000-10M | DC-2000-15M | DC-3000-5H | DC-3000-8M | DC-3000-10M | DC-3000-15M | ||
System Specifications | Table Size | in | □ 15.7 | □ 23.6 | □ 31.5 | □ 39.3 | □ 19.6 | □ 31.5 | □ 39.3 | □ 59 | □ 19.6 | □ 31.5 | □ 39.3 | □ 59 | |
Rated Force | Sine | lbf | 2,2 | 2,2 | 2,2 | 2,2 | 4,4 | 4,4 | 4,4 | 4,4 | 6,6 | 6,6 | 6,6 | 6,6 | |
Random | lbf | 1,1 | 1,1 | 1,1 | 1,1 | 2,2 | 2,2 | 2,2 | 2,2 | 3,3 | 3,3 | 3,3 | 3,3 | ||
Shock | lbf | 3,3 | 3,3 | 3,3 | 3,3 | 6,6 | 6,6 | 6,6 | 6,6 | 9,9 | 9,9 | 9,9 | 9,9 | ||
Maximum Acceleration | g | 11.0 | 7.6 | 5.5 | 3.3 | 15.3 | 8.3 | 6.8 | 2.9 | 20.0 | 14.2 | 9.3 | 4.8 | ||
Maximum Velocity | in/s | 39.4 | 39.4 | 39.4 | 39.4 | 39.4 | 39.4 | 39.4 | 35.4 | 39.4 | 39.4 | 39.4 | 35.4 | ||
Maximum Displacement | inp-p | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Armature Mass | lbs | 200 | 290 | 400 | 660 | 290 | 530 | 640 | 1,5 | 330 | 460 | 700 | 1,37 | ||
Maximum Frequency | Horizontal | Hz | 1 | 800 | 700 | 350 | 800 | 500 | 350 | 250 | 800 | 500 | 350 | 250 | |
Vertical | Hz | 1 | 1 | 700 | 500 | 800 | 800 | 500 | 350 | 800 | 800 | 500 | 350 | ||
Maximum Load | lbs | 220 | 220 | 440 | 440 | 440 | 660 | 1,1 | 1,1 | 440 | 660 | 1,1 | 1,1 | ||
Power Requirements | kVA | 25 | 25 | 25 | 25 | 43 | 43 | 43 | 43 | 52 | 52 | 52 | 52 | ||
Primary Cooling Water | gal/min | – | – | – | – | – | – | – | – | – | – | – | – |
System Model | Unit | DC-5000-6H | DC-5000-8H | DC-5000-10M | DC-5000-15M | DC-6000-6H | DC-6000-8H | DC-6000-10M | DC-6000-15M | ||
System Specifications | Table Size | in | □ 23.6 | □ 31.5 | □ 39.3 | □ 59 | □ 23.6 | □ 31.5 | □ 39.3 | □ 59 | |
Rated Force | Sine | lbf | 11 | 11 | 11 | 11 | 13,87 | 13,87 | 13,87 | 13,87 | |
Random | lbf | 6,6 | 6,6 | 5,5 | 5,5 | 8,3 | 8,3 | 6,9 | 6,9 | ||
Shock | lbf | 16,5 | 16,5 | 13,2 | 13,2 | 20,8 | 20,8 | 16,6 | 16,6 | ||
Maximum Acceleration | g | 35.7 | 20.8 | 16.6 | 6.0 | 39.3 | 27.3 | 10.4 | 7.6 | ||
Maximum Velocity | in/s | 39.4 | 39.4 | 35.4 | 35.4 | 39.4 | 39.4 | 35.4 | 35.4 | ||
Maximum Displacement | inp-p | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Armature Mass | lbs | 310 | 530 | 660 | 1,81 | 350 | 510 | 1,32 | 1,81 | ||
Maximum Frequency | Horizontal | Hz | 800 | 700 | 350 | 250 | 800 | 700 | 350 | 250 | |
Vertical | Hz | 1 | 800 | 500 | 350 | 1 | 800 | 500 | 350 | ||
Maximum Load | lbs | 660 | 660 | 1,1 | 1,54 | 660 | 300 | 1,1 | 1,54 | ||
Power Requirements | kVA | 75 | 75 | 73 | 73 | 93 | 93 | 91 | 91 | ||
Primary Cooling Water | gal/min | 52 | 52 | 50 | 50 | 61 | 61 | 59 | 59 |
*Depending on the reference PSD or other operating conditions such as the specimen, one part of the controlled response may deviate from the reference PSD. |
*The above is just an example. Specifications may be changed depending on test conditions. Please contact us for more information. |