System Model | Unit | K030/SA4 HAG | K062/SA8 HAG | K080/SA10 HAG | K100A/SA14 HAG | K125A/SA18 HAG | K100LS/SA16 HAG | K125LS/SA20 HAG | K160/SA20 HAG | K200/SA24 HAG | K350/SA36 HAG | |||
System Specifications | Frequency Range | Hz | 0-3000 | 0-2500 | 0-2500 | 0-2500 | 0-2500 | 0-2000 | 0-2000 | 0-2000 | 0-2000 | 0-2000 | ||
Rated Force | Sine | kN | 31 | 62 | 80 | 100 | 125 | 100 | 125 | 160 | 200 | 350 | ||
Random | kN rms | 22 | 62 | 80 | 100 | 125 | 100 | 125 | 160 | 200 | 315 | |||
Shock | kN | 62 | 123 | 160 | 200 | 250 | 200 | 250 | 320 | 400 | 700 | |||
Maximum Acc. | Sine | m/s² | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 800 | 1 | 1 | ||
Random | m/s² rms | 557 | 700 | 700 | 700 | 700 | 700 | 700 | 560 | 700 | 700 | |||
Shock | m/s² peak | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1,6 | 2 | 2 | |||
Maximum Vel. | Sine | m/s | 1.8 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Shock | m/s peak | 1.8 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.4 | 2.4 | 3.5 | |||
Maximum Disp. (Sine) | mmp-p | 51 | 51 | 51 | 51 | 51 | 100 | 100 | 76.2 | 76.2 | 76.2 | |||
Maximum Travel | mmp-p | 58 | 60 | 59 | 62 | 62 | 132 | 132 | 86 | 86 | 94 | |||
Maximum Load | kg | 500 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | |||
Power Requirements | kVA | 49 | 87 | 100 | 150 | 170 | 170 | 190 | 270 | 300 | 325 | |||
Breaker Capacity | A | 175 | 350 | 350 | 600 | 600 | 600 | 700 | - | - | - | |||
Vibration Generator | Model | K030 | K060 | K080 | K125A | K125A | K125LS | K125LS | K200 | K200 | K350 | |||
Armature Mass | kg | 27 | 40 | 60 | 80 | 80 | 100 | 100 | 200 | 200 | 350 | |||
Armature Diameter | φmm | 320 | 400 | 446 | 560 | 560 | 560 | 560 | 650 | 650 | 760 | |||
Allowable Eccentric Moment | N・m | 980 | 980 | 1,55 | 2,45 | 2,45 | 2,45 | 2,45 | 4,9 | 4,9 | 4,9 | |||
Dimensions | Width | mm | 1,1 | 1,38 | 1,595 | 1,776 | 1,776 | 1,99 | 1,99 | 2,465 | 2,465 | 3,02 | ||
Height | mm | 1,09 | 1,085 | 1,2 | 1,373 | 1,373 | 1,546 | 1,546 | 1,908 | 1,908 | 2,306 | |||
Depth | mm | 824 | 1 | 1,05 | 1,3 | 1,3 | 1,37 | 1,37 | 1,74 | 1,74 | 2,08 | |||
Shaker Body Diameter | φmm | 760 | 900 | 1 | 1,1 | 1,1 | 1,1 | 1,1 | 1,26 | 1,26 | 1,63 | |||
Mass | kg | 3 | 3,7 | 5 | 7 | 7 | 8 | 8 | 16 | 16 | 42 | |||
Power Amplifier | Model | SA4HAG-K30 | SA8HAG-K60 | SA10HAG-K80 | SA14HAG-K125A | SA18HAG-K125A | SA16HAG-K125LS | SA20HAG-K125LS | SA20HAG-K200 | SA24HAG-K200 | SA36HAG-K350 | |||
Maximum Output | kVA | 33 | 60 | 100 | 98 | 124 | 124 | 155 | 256 | 320 | 400 | |||
Dimensions | Width | mm | 580 | 1,16 | 1,16 | 1,74 | 1,74 | 1,74 | 1,74 | 2,9 | 2,9 | 4,06 | ||
Height | mm | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | |||
Depth | mm | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | |||
Mass | kg | 950 | 1,35 | 1,5 | 2,5 | 2,6 | 2,6 | 3,3 | 4,85 | 5 | 5,45 | |||
Controller | Vibration Controller | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | |||
Cooling | Cooling Method | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | |||
Primary Cooling Water | ℓ/min | 195 | 260 | 390 | 390 | 390 | 390 | 390 | 650 | 650 | 690 | |||
Heat Exchanger | Dimensions | Width | mm | 580 | 580 | 580 | 580 | 580 | 580 | 580 | 1,05 | 1,05 | 1,2 | |
Height | mm | 1,7 | 1,7 | 1,7 | 1,7 | 1,7 | 1,7 | 1,7 | 1,9 | 1,9 | 1,95 | |||
Depth | mm | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 800 | 800 | 1,4 | |||
Mass | kg | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 600 | 600 | 950 |
*Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
*Power supply: 3-phase 200/220/240/380/400/415 V (K200 and K350 is AC380/400/415V) , 50/60 Hz. A transformer is required for other supply voltages. |
*If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 1.4 m/s. |
*Breaker capacity for 200 V. |
*Bypass circuit is needed. Please contact IMV or your local distributor for further information. |
*An export license is required for exporting the shaker system of over 50 kN sine force. |
*The specification shows the maximum system performance. For long-duration tests, system must be de-rated up to 70%. |
*Continuous use at maximum levels may cause failure. Please contact IMV if your system operates at more than 70%. |
*For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
*Frequency range values vary according to the sensor and vibration controller. |
*Armature mass and acceleration may change when a chamber is added. |
*Mass and dimensions may change for CE-marked systems. |
ECO
System Model | Unit | K030/EM4 HAG | K062/EM8 HAG | K080/EM1 0HAG | K100A/EM1 4HAG | K125A/EM1 8HAG | K100LS/EM 16HAG | K125LS/EM 20HAG | K160/EM 20HAG | K200/EM 24HAG | K350/EM 36HAG | |||
System Specifications | Frequency Range | Hz | 0-3000 | 0-2500 | 0-2500 | 0-2500 | 0-2500 | 0-2000 | 0-2000 | 0-2000 | 0-2000 | 0-2000 | ||
Rated Force | Sine | kN | 31 | 62 | 80 | 100 | 125 | 100 | 125 | 160 | 200 | 350 | ||
Random | kN rms | 22 | 62 | 80 | 100 | 125 | 100 | 125 | 160 | 200 | 315 | |||
Shock | kN | 62 | 123 | 160 | 200 | 250 | 200 | 250 | 320 | 400 | 700 | |||
Maximum Acc. | Sine | m/s² | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 800 | 1 | 1 | ||
Random | m/s² rms | 557 | 700 | 700 | 700 | 700 | 700 | 700 | 560 | 700 | 700 | |||
Shock | m/s² peak | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1,6 | 2 | 2 | |||
Maximum Vel. | Sine | m/s | 1.8 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Shock | m/s peak | 1.8 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.4 | 2.4 | 3.5 | |||
Maximum Disp. (Sine) | mmp-p | 51 | 51 | 51 | 51 | 51 | 100 | 100 | 76.2 | 76.2 | 76.2 | |||
Maximum Travel | mmp-p | 58 | 60 | 59 | 62 | 62 | 132 | 132 | 86 | 86 | 94 | |||
Maximum Load | kg | 500 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | |||
Power Requirements | kVA | 49.0 | 87 | 100 | 150 | 170 | 170 | 190 | 270 | 300 | 325 | |||
Breaker Capacity | A | 175 | 350 | 350 | 600 | 600 | 600 | 700 | - | - | - | |||
Vibration Generator | Model | K030 | K060 | K080 | K125A | K125A | K125LS | K125LS | K200 | K200 | K350 | |||
Armature Mass | kg | 27 | 40 | 60 | 80 | 80 | 100 | 100 | 200 | 200 | 350 | |||
Armature Diameter | φmm | 320 | 400 | 446 | 560 | 560 | 560 | 560 | 650 | 650 | 760 | |||
Allowable Eccentric Moment | N・m | 980 | 980 | 1,55 | 2,45 | 2,45 | 2,45 | 2,45 | 4,9 | 4,9 | 4,9 | |||
Dimensions | Width | mm | 1,1 | 1,38 | 1,595 | 1,776 | 1,776 | 1,99 | 1,99 | 2,465 | 2,465 | 3,02 | ||
Height | mm | 1,09 | 1,085 | 1,2 | 1,373 | 1,373 | 1,546 | 1,546 | 1,908 | 1,908 | 2,306 | |||
Depth | mm | 824 | 1 | 1,05 | 1,3 | 1,3 | 1,37 | 1,37 | 1,74 | 1,74 | 2,08 | |||
Shaker Body Diameter | φmm | 760 | 900 | 1 | 1,1 | 1,1 | 1,1 | 1,1 | 1,26 | 1,26 | 1,63 | |||
Mass | kg | 3 | 3,7 | 5 | 7 | 7 | 8 | 8 | 16 | 16 | 42 | |||
Power Amplifier | Model | EM4HAG-K30 | EM8HAG-K60 | EM10HAG-K80 | EM14HAG-K125A | EM18HAG-K125A | EM16HAG-K125LS | EM20HAG-K125LS | EM20HAG-K200 | EM24HAG-K200 | EM36HAG-K350 | |||
Maximum Output | kVA | 33 | 60 | 100 | 98 | 124 | 124 | 155 | 256 | 320 | 400 | |||
Dimensions | Width | mm | 1,16 | 1,16 | 1,16 | 1,74 | 1,74 | 1,74 | 1,74 | 2,9 | 2,9 | 4,06 | ||
Height | mm | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | |||
Depth | mm | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | |||
Mass | kg | 1,3 | 1,35 | 1,5 | 2,5 | 2,6 | 2,65 | 3,35 | 4,85 | 5 | 5,45 | |||
Controller | Vibration Controller | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | |||
Cooling | Cooling Method | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | |||
Primary Cooling Water | ℓ/min | 195 | 260 | 390 | 390 | 390 | 390 | 390 | 650 | 650 | 690 | |||
Heat Exchanger | Dimensions | Width | mm | 580 | 580 | 580 | 580 | 580 | 580 | 580 | 1,05 | 1,05 | 1,2 | |
Height | mm | 1,7 | 1,7 | 1,7 | 1,7 | 1,7 | 1,7 | 1,7 | 1,9 | 1,9 | 1,95 | |||
Depth | mm | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 800 | 800 | 1,4 | |||
Mass | kg | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 600 | 600 | 950 |
*Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
*Power supply: 3-phase 200/220/240/380/400/415 V (K200 and K350 is AC380/400/415V) , 50/60 Hz. A transformer is required for other supply voltages. |
*If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 1.4 m/s. |
*Breaker capacity for 200 V. |
*Bypass circuit is needed. Please contact IMV or your local distributor for further information. |
*An export license is required for exporting the shaker system of over 50 kN sine force. |
*The specification shows the maximum system performance. For long-duration tests, system must be de-rated up to 70%. |
*Continuous use at maximum levels may cause failure. Please contact IMV if your system operates at more than 70%. |
*For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
*Frequency range values vary according to the sensor and vibration controller. |
*Armature mass and acceleration may change when a chamber is added. |
*Mass and dimensions may change for CE-marked systems. |
US:ECO
System Model | Unit | K080/EM10HAG | K125A/EM18HAG | K125LS/EM20HAG | K200/EM24HAG | K350/EM36HAG | |||
System Specifications | Frequency Range | Hz | 0-2500 | 0-2500 | 0-2000 | 0-2000 | 0-2000 | ||
Rated Force | Sine | lbf | 18 | 28,1 | 28,1 | 45 | 78,7 | ||
Random | lbf rms | 18 | 28,1 | 28,1 | 45 | 70,8 | |||
Shock | lbf | 36 | 56,2 | 56,2 | 90 | 157,3 | |||
Maximum Acc. | Sine | g | 102 | 102 | 102 | 102 | 102 | ||
Random | g rms | 71 | 71 | 71 | 71 | 71 | |||
Shock | g peak | 204 | 204 | 204 | 204 | 204 | |||
Maximum Vel. | Sine | in/s | 79 | 79 | 79 | 79 | 79 | ||
Shock | in/s peak | 79 | 79 | 79 | 94 | 138 | |||
Maximum Disp. (Sine) | inp-p | 2.0 | 2.0 | 4.0 | 3.0 | 3.4 | |||
Maximum Travel | inp-p | 2.3 | 2.4 | 5.2 | 3.4 | 3.7 | |||
Maximum Load | lbs | 2,2 | 4,4 | 4,4 | 4,4 | 6,615 | |||
Power Requirements | kVA | 100.0 | 170 | 190 | 300 | 325 | |||
Breaker Capacity | A | 150 | 250 | 300 | 500 | 630 (total) | |||
Vibration Generator | Model | K080 | K125A | K125LS | K200 | K350 | |||
Armature Mass | lbs | 132 | 177 | 221 | 441 | 772 | |||
Armature Diameter | φin | 17.6 | 22 | 22.0 | 25.6 | 29.9 | |||
Allowable Eccentric Moment | lbf in | 13,7 | 21,7 | 21,7 | 43,4 | 43,4 | |||
Dimensions | Width | in | 63 | 70 | 78 | 97 | 119 | ||
Height | in | 48 | 54 | 61 | 75 | 91 | |||
Depth | in | 41 | 51 | 54 | 69 | 82 | |||
Shaker Body Diameter | φin | 39 | 43 | 43 | 50 | 64 | |||
Mass | lbs | 11,025 | 15,435 | 17,64 | 35,28 | 92,595 | |||
Power Amplifier | Model | EM10HAG-K80 | EM18HAG-K125A | EM20HAG-K125LS | EM24HAG-K200 | EM36HAG-K350 | |||
Maximum Output | kVA | 100 | 124 | 155 | 320 | 400 | |||
Amplifier Bay | s | 2 | 3 | 3 | 5 | 7 | |||
Dimensions | Width | in | 46 | 69 | 69 | 114 | 161 | ||
Height | in | 77 | 77 | 77 | 77 | 77 | |||
Depth | in | 34 | 34 | 34 | 34 | 34 | |||
Mass | lbs | 3,31 | 5,73 | 7,275 | 11,02 | 12,015 | |||
Controller | Vibration Controller | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | |||
Cooling | Cooling Method | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | Shaker: Water Cooling Amp: Air Cooling | |||
Required Cooling Water Flow Rate | Δt = 5°C | gal/min | 103 | 103 | 103 | 172 | 182 | ||
Δt = 10°C | 25 | 39 | 39 | 60 | 66 | ||||
Heat Exchanger | Dimensions | Width | in | 23 | 23 | 23 | 41 | 47 | |
Height | in | 67 | 67 | 67 | 75 | 77 | |||
Depth | in | 34 | 34 | 34 | 32 | 55 | |||
Mass | lbs | 885 | 885 | 885 | 1,325 | 1,325 |
*Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
* Power supply: 3-phase 220/480V, 60Hz. A transformer is required for other supply voltages. |
* If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 5.5 in/s. |
*Breaker capacity for 480V. |
*Bypass circuit is needed. Please contact IMV or your local distributor for further information. |
* An export license is required for exporting a shaker system of over 11,240 lbf sine force. |
* For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
* Frequency range values vary according to sensor and vibration controller. |
*Armature mass and acceleration may change when a chamber is added. |
*Mass and dimensions may change for CE-marked systems. |