Features
• Adoption of an air type elevator unit allows for the drum to be easily replaced.
• The mechanically operated safety stopper safely and reliably prevents the drum can from falling off.
• A wide range of options is available.
• Performance and installation compatibility with previous drum can pump models.
• Applicable container: 200 kg drum (JIS product)
Specifications
Model | AELBPR08 | AELBPR10 | AELBPR20 | AELBPR40 | |
Pump | Discharge quantity (cm3/min(50/60Hz)) |
75/90 | 100/120 | 158/190 | 316/380 |
Max. operating pressure (MPa) | 21 | ||||
Safety valve pressure (MPa) | 25 | ||||
Motor specifications | 0.2 kW (speed reduction ratio 1/59) |
0.2 kW (speed reduction ratio 1/43) |
0.4 kW (speed reduction ratio 1/21) |
||
Grease used | NLGI #0 to #2 (Note, however, that the consistency will be 240 or more at the operating temperature.) |
||||
Elevator | Supply air pressure (MPa) | 0.4~0.5 | |||
Liftable weight (kg) | 80 | ||||
Total raise stroke (mm) |
950 | ||||
Total unit weight (kg) | Single line | 185 | |||
Dual line | 195 |
Note) When replacing the drum can, because the follower plate is tightly attached to the drum, ensure that air is supplied before removal.
Note) Residual grease amount is set at 8 L at the time of shipment. Amount can be changed upon arrival.