A new standard created by listening to our customers. A wider range of test requirements and higher test specifications.
A-series meets the needs for such a versatile test environment.
Advanced automatic energy saving, high level of functionality and a protected test environment.
A series improves the working environment of vibration testing.
Features
1. Improvement of performance
Improvement in excitation force
When compared with the conventional i & J series, the A series increases the relative excitation force.
・Increased force per system power requirement
・Increased force per system mass
・Increased force per system size
Improvement in excitation force
When compared with the conventional i- & J-series, the A-series has increased relative excitation force.
Standard 76.2 mmp-p displacement *Only for A30, A45, A65, A74
A-series has a displacement of 76.2 mmp-p (3-inch stroke), which provides a good balance within the specifications for velocity, acceleration and displacement. This single system can be used for a very wide variety of tests.
Increase in frequency range
In addition to the increased displacement of 76.2 mmp-p, the maximum frequency range is also increased when compared to the i- and J-series.
Introduction of new power module
By developing a power amplifier that uses a new next generation Silicon Carbide power module, IMV has achieved low noise and high efficiency. This new power module is standard-issue for all A-series models.
2. User friendly and Secure
Advanced automatic energy saving, high level of functionality and a protected test environment. A-series provides a better working environment for vibration testing.
Lower power consumption
In comparison with the same class of conventional systems (i,J-series), the A-series achieves lower power consumption. With an automatic energy-saving function increased energy saving is achieved across all force ranges.
International safety standards
A-series complies with international safety standards
3. User friendly principle
Rapid creation of a test from a set of pre-defined templates conforming to most international test standards.
LAUNCHER
Test file will be automatically generated upon selection of the test conditions defined by the test standards. Then, the test can be carried out just by pressing the start button.
In-built “Quick Help” provides guidance on each operation.
SYSTEM MONITOR
Statuses for vibration generator, amplifier test proceeding, and specimen can be observed on a PC or tablet by either wired or wireless LAN. Solutions can be seen on the Web browser upon the occurrence of any error. Installation of additional software is not necessary for PC or tablet.
Home screen
Home screen (error)
Eco screen
Camera screen
Manual link screen
Specification
Standard
System Model | Unit | A11/SA1HAG | A22/SA2HAG | A30/SA3HAG | A45/SA4HAG | A65/SA5HAG | |||
System Specifications | Frequency Range | Hz | 0-4500 | 0-3300 | 0-2600 | 0-2600 | 0-2600 | ||
Rated Force | Sine | kN | 11 | 22 | 30 | 45 | 65 | ||
Random | kN rms | 11 | 22 | 30 | 45 | 65 | |||
Shock | kN | 22 | 44 | 60 | 90 | 130 | |||
Maximum Acc. | Sine | m/s² | 1 | 1 | 900 | 900 | 900 | ||
Random | m/s² rms | 630 | 630 | 630 | 630 | 630 | |||
Shock | m/s² peak | 2 | 2 | 1,818 | 1,8 | 1,806 | |||
Maximum Vel. | Sine | m/s | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Shock | m/s peak | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | |||
Maximum Disp. (Sine) | mmp-p | 51 | 51 | 76.2 | 76.2 | 76.2 | |||
Maximum Travel | mmp-p | 64 | 64 | 82 | 82 | 82 | |||
Maximum Load | kg | 200 | 300 | 400 | 600 | 1 | |||
Power Requirements | kVA | 20.4 | 30 | 36 | 57 | 83 | |||
Breaker Capacity | A | 75 | 100 | 125 | 200 | 300 | |||
Vibration Generator | Model | A11 | A22 | A30 | A45 | A65 | |||
Armature Mass | kg | 11 | 22 | 33 | 50 | 72 | |||
Armature Diameter | φmm | 210 | 280 | 290 | 436 | 446 | |||
Allowable Eccentric Moment | N・m | 294 | 700 | 850 | 1,55 | 1,55 | |||
Dimensions | Width | mm | 946 | 1,038 | 1,1 | 1,232 | 1,31 | ||
Height | mm | 827 | 955 | 1,048 | 1,215 | 1,253 | |||
Depth | mm | 676 | 775 | 840 | 1,04 | 1,04 | |||
Shaker Body Diameter | φmm | 585 | 678 | 725 | 825 | 925 | |||
Mass | kg | 1,08 | 1,6 | 2 | 3 | 4,2 | |||
Power Amplifier | Model | SA1HAG-A11 | SA2HAG-A22 | SA3HAG-A30 | SA4HAG-A45 | SA5HAG-A65 | |||
Maximum Output | kVA | 12 | 24 | 31 | 44 | 68 | |||
Dimensions | Width | mm | 580 | 580 | 580 | 580 | 580 | ||
Height | mm | 1,95 | 1,95 | 1,95 | 1,95 | 1,95 | |||
Depth | mm | 850 | 850 | 850 | 850 | 850 | |||
Mass | kg | 280 | 350 | 520 | 900 | 1 | |||
Controller | Vibration Controller | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | See Vibration Controller K2 | |||
Cooling | Cooling Method | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | |||
Blower | Dimensions | Width | mm | 606 | 707 | 707 | 1,057 | 1,214 | |
Height | mm | 1,315 | 1,531 | 1,531 | 1,841 | 2,006 | |||
Depth | mm | 891 | 917 | 917 | 1,125 | 1,124 | |||
Mass | kg | 125 | 210 | 210 | 250 | 420 | |||
Wattage | kw | 3.7 | 5.5 | 5.5 | 11 | 18.5 | |||
Duct Hose Diameter | φ | 125 | 200 | 200 | 250 | 250 |
*Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
*Power supply: 3-phase 200/220/380/400/415 V (A74 is only AC380/400/415 V), 50/60 Hz. A transformer is required for other supply voltages. |
*Breaker capacity for AC 200 V. |
*Above 4000 Hz, the force rolls-off at a rate of -6 dB/oct. |
*Above 2000 Hz, the force rolls-off at a rate of -12 dB/oct. |
*Specification above applies to 60 Hz. Dimensions change for 50 Hz. |
*An export license is required for exporting the shaker system of over 50 kN sine force. |
*The specification shows the maximum system performance. For long-duration tests, system must be de-rated up to 70%. |
Continuous use at maximum levels may cause failure. Please contact IMV if your system operates at more than 70%. |
*For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
*Frequency range values vary according to the sensor and vibration controller. |
*Armature mass and acceleration may change when a chamber is added. |
*Mass and dimensions may change for CE-marked systems. |