Specifications

(50/60Hz)

Mounting type Side-mounting
Cooling capacity(W) 900/1000
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 20~50
Use Area Humidity(%RH) 10~85 (No condensation)
External dimensions(mm) H850×W350×D230
Weight(kg) 29
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Single-phase AC200
Consumption Current: Rated(A) 2.8/2.5
Consumption Current: MAX(A) 3.2/3.1
Starting Current(A) 9.1/8.7
Consumption wattage: Rated(W) 460/480
Consumption wattage: MAX(W) 565/595
Noise Resistance LEVEL4 by Fast Transient / Burst Immunity Test
Vibration Resistance 5Hz frequency 20mm total amplitude
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R134a 280g
Noise (dB (A)) Approx. 74/76
External Output Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal temperature is 35°C. (measurement conditions: JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : use area temperature 35°C , use area humidity RH 40%.
MAX value: Value at the maximum ambient temperature allowed and an operating ambient humidity of 40%RH.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 6 (M6×L20)
Drain hose 5m
Insulation lock ties 1
Spacer 6 (6.5×5.5L)
Instruction manual 1

Replacement parts list

Condenser side Fan Circulating fan for A1020L-DF
Evaporator side Fan Outside air fan for A1020L-DF
Filter ENC-F-51 (2 pieces)
Control PCB Substrate for A1020L-DF

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

External dimensions

ENC-A1020L-DF External dimensions

(1) Power line : Cord length 3m
(2) Cooling operation output Line : Cord length 3m
(3) Alarm Output Line : Cord length 3m

Diagram of Panel Cutout

ENC-A1020L-DF Diagram of Panel Cutout

[Standard panel cut]
*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.