Specifications

(50/60Hz)

Mounting type Side-mounting
Cooling capacity(W) 950/1100
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 20~50
Use Area Humidity(%RH) 10~85 (No condensation)
External dimensions(mm) H730×W300×D230
Weight(kg) 23
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Single-phase AC100
Consumption Current: Rated(A) 5.5/4.8
Consumption Current: MAX(A) 6.7/6.8
Starting Current(A) 15.6/14.7
Consumption wattage: Rated(W) 450/470
Consumption wattage: MAX(W) 620/680
Vibration Resistance Equivalent to JIS Z 0200 Level1
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R134a 230g
Noise (dB (A)) Approx. 64/68
External Output Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Allowable ambient temperature: When used continuously at a low ambient temperature (15 to 20 °C or less), be sure to turn off the power supply as there is a possibility the compressor may operate at a high load.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 6 (M6×L20)
Drain hose 2m
Insulation lock ties 1
Washer 2
Spacer 6
Air direcrion louver 1
Mounting bolt for louver 2
Packing (Long) 2 / (Short) 2
Instruction manual 1

Replacement parts list

Condenser side Fan Circulating fan for G1110L
Evaporator side Fan Outside air fan for G1110L
Filter ENC-F-21(2 pieces)
Control PCB Substrate for G1110L/G1120L

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

External dimensions

ENC-G1110L External dimensions

(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m

Diagram of Panel Cutout

ENC-G1110L Diagram of Panel Cutout

*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.
*The power cable retrieval section is either slanted or machined to a diameter or φ50.