Control panel cooling unit – ENC-G310LE

Thương hiệu : Apiste

Cam kết và Chính sách của TECHNO

  • icon

    Cam kết 100% Hàng chính hãng

  • icon

    Chất lượng cao, đáp ứng đa dạng nhu cầu

  • icon

    Tư vấn kỹ thuật toàn diện và chuyên sâu

  • icon

    Chính sách bảo hành và hỗ trợ nhanh chóng

Specifications

(50/60Hz)

Mounting type Side-mounting
Cooling capacity(W) 280/300
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 20~50
Use Area Humidity(%RH) 10~85 (No condensation)
External dimensions(mm) H590×W200×D250
Weight(kg) 18
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Single-phase AC100
Consumption Current: Rated(A) 3.5/3.3
Consumption Current: MAX(A) 3.7/3.8
Starting Current(A) 7.4/7.7
Consumption wattage: Rated(W) 300/315
Consumption wattage: MAX(W) 340/370
Vibration Resistance Equivalent to JIS Z 0200 Level1
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R134a 87g
Noise (dB (A)) Approx. 59/63
External Output Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Non-draining function operating range: At an ambient temperature/panel internal temperature of 35 °C or less and an ambient humidity/panel internal humidity of 85% or less.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 6 (M6×L20)
Drain hose 1 (2m)
Insulation lock ties 1
Spacer 6
Packing (Long) 2 / (Short) 2
Instruction manual 4

Replacement parts list

Condenser side Fan Circulating fan for G310LE
Evaporator side Fan Outside air fan for G310LE
Filter ENC-F-64
Evaporization filter Vaporization filter for G310LE
Control PCB Substrate for G310LE

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

External dimensions

ENC-G310LE External dimensions

(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m

Diagram of Panel Cutout

ENC-G310LE Diagram of Panel Cutout

[Standard panel cut]
*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.