Non-freon air-cooled oil chillers – VSC-N1500
Cam kết và Chính sách của TECHNO
-
Cam kết 100% Hàng chính hãng
-
Chất lượng cao, đáp ứng đa dạng nhu cầu
-
Tư vấn kỹ thuật toàn diện và chuyên sâu
-
Chính sách bảo hành và hỗ trợ nhanh chóng
This is the industry’s first R1234yf non-Freon coolant compatible oil chiller. With a global warming potential of less than 1 and ozone depletion potential of 0, this coolant is an environmentally-friendly alternative to Freon. And, of course, these oil chillers are exempt from the Fluorocarbon Emissions Law. VSC-N Series oil chillers greatly reduce maintenance time and labor because they do not need a basic inspection every three months. What’s more, they reduce costs associated with collecting Freon when discarding and dismantling equipment.
Specifications
| Cooling method | Air-cooled type |
|---|---|
| Cooling capacity(W) | 1350/1580 |
| Usable Oil | Lubricating oil, petroleum hydraulic oil |
| Setting criteria / tuned type | Room temperature, unit temperature |
| Control target / tuned type | Outlet opening oil temperature |
| Temperature control range / tuned type(℃) | Within -9.9 to +9.9 of the set standard temperature |
| Control target / fixed type | Outlet opening oil temperature |
| Temperature control range / fixed type(℃) | 5~45 |
| Temperature control accuracy (°C) | ±0.1 |
| Oil viscosity (mm2/s) | 1.4~200(ISO VG2~68) |
| Use Area Temperature(℃) | 5~45 |
| Power-supply voltage(V) | Three-phase AC200 |
| Power-supply voltage(V) | 2.8/2.6 |
| Consumption current(W) | 600/720 |
| External dimensions(mm) | H720×W360×D449 |
| Weight(kg) | 53 |
| Coating Color | Munsell N7 |
| Pipe connection / Oil outlet | Rc3/4 |
| Pipe connection / Oil intlet | Rc3/4 |
| Pump / rated output(W) | 400 |
| Pump / Discharge rate(ℓ/min) | 12/14.4 |
| Relief valve pressure setting (MPa) | 0.6 |
| Refrigerant / Type | R1234yf |
| Refrigerant / Fill ration(g) | 306 |
| Noise (dB (A)) | 70 |
| Safety circuit / Compressor | Thermal protector, electromagnetic switch |
| Safety circuit / Cooling cycle | Pressure switch |
| Safety circuit / Pump | Electromagnetic switch, relief valve |
| Input/output / Alarm output | Non-voltage, normally open or normal close can be selected |
| Input/output / Run/stop input | Non-voltage normally open |
*Cooling capacity, current consumption, and power consumption values are based on a 35ºC room temperature and 35ºC oil temperature (ISO VG5).
*Do not use machining fluids, grinding fluids, water and water soluble liquids, pharmaceutical and food product liquids, gasoline, kerosene, thinner and other highly volatile, low-lubricant fluids, or flame-retardant hydraulic oil.
Temperature control precision is based on the temperature gage reading under constant load.
* Maintain power supply voltage within ±10% of rated voltage.
External dimensions

① Oil Inlet Rc3/4
② Oil Outlet Rc3/4
③ Hanging bracket
④ Control Panel
⑤ Filter
⑥ External input/output wiring opening Φ22
⑦ Power source wiring opening Φ22
⑧ External temperature thermistor wiring opening Φ22