Measurement Range:K -200 to 1370°C / E -200 to 800°C

ホールドHOLD
The thermometer stops measurement
by the HOLD key and holds the present readings.
オートパワーオフAuto power-off
The thermometer will turn the power off automatically after 5minutes.
分解能切替Resolution change
Press the [RESO] key to change the resolution of readings.
PVホールドP/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
バックライトBacklight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
画像Memory function
Stores readings at user-selected time intervals.
User specified time interval and the remaining amount of memory are displayed on the sub-display.

(Temperature probes not included)

Specifications

Model HR-1500
Display LCD
Waterproof specifications
Input connector ASP
Input type Thermocouple Input: Type E, K
Channel 1ch
Signal source resistance MAX.1k ohm
Measurement Range 1°C Resolution E -200 to 800°C
K -200 to 1370°C
0.1°C Resolution E -104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

K -104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

Measurement Accuracy 1°C Resolution 0°C to ± (0.1% of reading +1°C)
to 0°C ± (0.5% of reading +1°C)
0.1°C Resolution 0°C to ± (0.05% of reading + 0.2°C)
to 0°C ± (0.15% of reading + 0.2°C)
Reference junction compensation accuracy ±0.2°C at 25°C±10°C
Temperature Coefficient*1 ±0.02×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.3°C is added at room temp. of 0°C or 50°C)
Operation Environment 0 to 50°C, 0 to 80%RH (Non condensing)
Storage Environment -20 to 50°C, 0 to 85%RH (Non condensing)
Battery life approx.550h
Power supply(Dry battery) 4 AA Alkaline batteries
Power supply(AC power) option available
Sampling rate approx.200ms
Linearlizer Digital Linearizer method (Compliant with JIS C1602-2015)
Dimensions(mm) approx. 82(w)×166(H)×36(D)  [Protruded parts excluded]
Weight approx. 350g [Include Batteries]
Supplied accessories Manual,Test report,Soft case,
Hand strap,4 AA Alkaline batteries
Optional accessories Communication cable, Software(AMS-350)
Memory function TABLE1
Compatible standards EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)

RoHS:IEC EN 63000:2018

*1 Only when the temp. exceeds 25°C±10°C

※ Details of typeJ,T,R(option)

TABLE1 Memory function

Time interval second:1, 5, 10, 30 minutes:1, 5, 10, 30, 60 and manual memory
Memory capacity 19999data

Software

Download data

画像

Data stored in memory can be transmitted to a personal computer through USB interface and can converted into CSV files.

Operational environment OS software(AMS-350)

OS Windows® 8.1、Windows® 10
System 32bit / 64bit

* All PCs under the recommended environment are not guaranteed to work successfully with AMS-950.
* AMS-950 can be used only by the user that has a system administrative right (Administrator)
* Microsoft® Windows® 8.1, Windows® 10, and Excel® are registered trademarks of Microsoft Corporation in the United States and other countries.