Improved operational and testing efficiency.
Multiaxial (switching) vibration testing is used primarily to ‘improve testing and working efficiency’.
Specifications
Standard
System Model | Unit | TC-1000-4H | TC-1000-6H | TC-1000-8H | TC-1000-10M | TC-2000-5H | TC-2000-8M | TC-2000-10M | TC-2000-15M | TC-3000-5H | TC-3000-8M | TC-3000-10M | TC-3000-15M | ||
System Specifications | Table Size | mm | □ 400 | □ 600 | □ 800 | □ 1000 | □ 500 | □ 800 | □ 1000 | □ 1500 | □ 500 | □ 800 | □ 1000 | □ 1500 | |
Rated Force | Sine | kN | 9.8 | 9.8 | 9.8 | 9.8 | 19.6 | 19.6 | 19.6 | 19.6 | 29.4 | 29.4 | 29.4 | 29.4 | |
Random | kN | 4.9 | 4.9 | 4.9 | 4.9 | 9.8 | 9.8 | 9.8 | 9.8 | 14.7 | 14.7 | 14.7 | 14.7 | ||
Shock | kN | 14.7 | 14.7 | 14.7 | 14.7 | 29.4 | 29.4 | 29.4 | 29.4 | 44.1 | 44.1 | 44.1 | 44.1 | ||
Maximum Acceleration | m/s² | 98 | 65 | 42 | 33 | 163 | 98 | 65 | 30 | 196 | 113 | 73 | 43 | ||
Maximum Velocity | m/s | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 0.9 | 1.0 | 1.0 | 1.0 | 0.9 | ||
Maximum Displacement | mmp-p | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | ||
Armature Mass | kg | 100 | 150 | 230 | 290 | 120 | 200 | 300 | 640 | 150 | 260 | 400 | 680 | ||
Maximum Frequency | Horizontal | Hz | 1 | 800 | 700 | 350 | 800 | 500 | 350 | 250 | 800 | 500 | 350 | 250 | |
Vertical | Hz | 1 | 1 | 700 | 500 | 800 | 800 | 500 | 350 | 800 | 800 | 500 | 350 | ||
Maximum Load | kg | 100 | 100 | 200 | 200 | 200 | 300 | 500 | 500 | 200 | 300 | 500 | 500 | ||
Power Requirements | kVA | 27 | 27 | 27 | 27 | 43 | 43 | 43 | 43 | 52 | 52 | 52 | 52 | ||
Primary Cooling Water | ℓ/min | – | – | – | – | – | – | – | – | – | – | – | – |
System Model | Unit | TC-5000-6H | TC-5000-8H | TC-5000-10M | TC-5000-15M | TC-6000-6H | TC-6000-8H | TC-6000-10M | TC-6000-15M | ||
System Specifications | Table Size | mm | □ 600 | □ 800 | □ 1000 | □ 1500 | □ 600 | □ 800 | □ 1000 | □ 1500 | |
Rated Force | Sine | kN | 49 | 49 | 49 | 49 | 61.7 | 61.7 | 61.7 | 61.7 | |
Random | kN | 29.4 | 29.4 | 24.5 | 24.5 | 37 | 37 | 30.8 | 30.8 | ||
Shock | kN | 73.5 | 73.5 | 58.8 | 58.8 | 92.5 | 92.5 | 74 | 74 | ||
Maximum Acceleration | m/s² | 306 | 222 | 158 | 67 | 342 | 257 | 199 | 84 | ||
Maximum Velocity | m/s | 1.0 | 1.0 | 0.9 | 0.9 | 1.0 | 1.0 | 0.9 | 0.9 | ||
Maximum Displacement | mmp-p | 51 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | ||
Armature Mass | kg | 160 | 220 | 310 | 730 | 180 | 240 | 310 | 730 | ||
Maximum Frequency | Horizontal | Hz | 800 | 700 | 350 | 250 | 800 | 700 | 350 | 250 | |
Vertical | Hz | 1 | 800 | 500 | 350 | 1 | 800 | 500 | 350 | ||
Maximum Load | kg | 300 | 300 | 500 | 700 | 300 | 300 | 500 | 700 | ||
Power Requirements | kVA | 77 | 77 | 75 | 75 | 93 | 93 | 91 | 91 | ||
Primary Cooling Water | ℓ/min | 195 | 195 | 190 | 190 | 230 | 230 | 225 | 225 |
* Depending on the reference PSD or other operating conditions such as the specimen, one part of the controlled response may deviate from the reference PSD. |
* The above is just an example. Specifications may be changed depending on test conditions. Please contact us for more information. |
US:Standard
System Model | Unit | TC-1000-4H | TC-1000-6H | TC-1000-8H | TC-1000-10M | TC-2000-5H | TC-2000-8M | TC-2000-10M | TC-2000-15M | TC-3000-5H | TC-3000-8M | TC-3000-10M | TC-3000-15M | ||
System Specifications | Table Size | in | □ 15.7 | □ 23.6 | □ 31.5 | □ 39.3 | □ 19.6 | □ 31.5 | □ 39.3 | □ 59 | □ 19.6 | □ 31.5 | □ 39.3 | □ 59 | |
Rated Force | Sine | lbf | 2,2 | 2,2 | 2,2 | 2,2 | 4,4 | 4,4 | 4,4 | 4,4 | 6,6 | 6,6 | 6,6 | 6,6 | |
Random | lbf | 1,1 | 1,1 | 1,1 | 1,1 | 2,2 | 2,2 | 2,2 | 2,2 | 3,3 | 3,3 | 3,3 | 3,3 | ||
Shock | lbf | 3,3 | 3,3 | 3,3 | 3,3 | 6,6 | 6,6 | 6,6 | 6,6 | 9,9 | 9,9 | 9,9 | 9,9 | ||
Maximum Acceleration | g | 10.0 | 6.6 | 4.3 | 3.4 | 16.6 | 10 | 6.6 | 3.1 | 20.0 | 11.5 | 7.4 | 4.4 | ||
Maximum Velocity | in/s | 39.4 | 39.4 | 39.4 | 39.4 | 39.4 | 39.4 | 39.4 | 35.4 | 39.4 | 39.4 | 39.4 | 35.4 | ||
Maximum Displacement | inp-p | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Armature Mass | lbs | 200 | 330 | 510 | 640 | 270 | 440 | 660 | 1,41 | 330 | 570 | 880 | 1,5 | ||
Maximum Frequency | Horizontal | Hz | 1 | 800 | 700 | 350 | 800 | 500 | 350 | 250 | 800 | 500 | 350 | 250 | |
Vertical | Hz | 1 | 1 | 700 | 500 | 800 | 800 | 500 | 350 | 800 | 800 | 500 | 350 | ||
Maximum Load | lbs | 220 | 220 | 440 | 440 | 440 | 660 | 1,1 | 1,1 | 440 | 660 | 1,1 | 1,1 | ||
Power Requirements | kVA | 27 | 27 | 27 | 27 | 43 | 43 | 43 | 43 | 52 | 52 | 52 | 52 | ||
Primary Cooling Water | gal/min | – | – | – | – | – | – | – | – | – | – | – | – |
System Model | Unit | TC-5000-6H | TC-5000-8H | TC-5000-10M | TC-5000-15M | TC-6000-6H | TC-6000-8H | TC-6000-10M | TC-6000-15M | ||
System Specifications | Table Size | in | □ 23.6 | □ 31.5 | □ 39.3 | □ 59 | □ 23.6 | □ 31.5 | □ 39.3 | □ 59 | |
Rated Force | Sine | lbf | 11 | 11 | 11 | 11 | 13,87 | 13,87 | 13,87 | 13,87 | |
Random | lbf | 6,6 | 6,6 | 5,5 | 5,5 | 8,3 | 8,3 | 6,9 | 6,9 | ||
Shock | lbf | 16,5 | 16,5 | 13,2 | 13,2 | 20,8 | 20,8 | 16,6 | 16,6 | ||
Maximum Acceleration | g | 31.2 | 22.6 | 16.1 | 6.8 | 34.9 | 26.2 | 20.2 | 8.6 | ||
Maximum Velocity | in/s | 39.4 | 39.4 | 35.4 | 35.4 | 39.4 | 39.4 | 35.4 | 35.4 | ||
Maximum Displacement | inp-p | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | ||
Armature Mass | lbs | 350 | 485 | 660 | 1,61 | 400 | 530 | 680 | 1,61 | ||
Maximum Frequency | Horizontal | Hz | 800 | 700 | 350 | 250 | 800 | 700 | 350 | 250 | |
Vertical | Hz | 1 | 800 | 500 | 350 | 1 | 800 | 500 | 350 | ||
Maximum Load | lbs | 660 | 660 | 1,1 | 1,54 | 660 | 660 | 1,1 | 1,54 | ||
Power Requirements | kVA | 77 | 77 | 75 | 75 | 93 | 93 | 91 | 91 | ||
Primary Cooling Water | gal/min | 52 | 52 | 50 | 50 | 61 | 61 | 59 | 59 |
*Depending on the reference PSD or other operating conditions such as the specimen, one part of the controlled response may deviate from the reference PSD. |
*The above is just an example. Specifications may be changed depending on test conditions. Please contact us for more information. |