Non-Contacting Electrostatic Voltmeter for EOS and ESD Processes

Advanced Energy’s Trek 542A provides accurate electrostatic surface measurements. Typical uses include semiconductor, LCD, electronic assembly, and ESD-sensitive applications.

  • Measurement Range: ±20 kV DC or peak AC
  • Measurement Accuracy: Better than ±5% of the reading ±0.2% of full-scale over a probe-to-surface separation of 15 to 60 mm
  • Alphanumeric LCD Display: 20 x 4 characters

*Specifications dependent on model

Overview

The Trek® 542A electrostatic voltmeter (pictured with the Model 542P-S probe) is configured with a miniature electrostatic field chopper probe. The probe can be remotely located and easily positioned within process equipment to provide highly accurate, non-contacting, DC-stable, spacing-independent voltage measurements in either ionized or non-ionized environments. The unit’s 20 x 4 alphanumeric LCD screen displays the present measured voltage, positive and negative peak voltage values, and additional menu information.

Benefits

  • Enable drift-free measurements
  • Benefit from visual and audible alarms that activate when preset voltage-threshold levels are reached
  • Remotely locate or easily position miniature field chopper probe
  • Use in ionized or non-ionized environments
  • Take spacing-independent voltage measurements

Features

  • Chopper probe is DC-stable with or without incident airflow
  • Analog voltage monitor output
  • USB and RS-232 serial ports
  • NIST-traceable calibration certificate provided with each unit
  • Walking test adapter kit available
  • Performance

    Measurement Ranges

    • 542A-1: 0 to ±10 kV DC or peak AC
    • 542A-2: 0 to ±20 kV DC or peak AC

    Speed of Response (10 to 90%)

    Less than 50 ms for a ±1 kV step

    Accuracy

    Better than ±5% of the reading ±0.2% of full-scale over a probe-to-surface separation of:

    • 542A-1: 15 mm to 30 mm
    • 542A-2: 30 mm to 60 mm

    Drift with Time

    Less than ±1% full scale, non-cumulative

  • Mechanical

    H x W x D

    97 x 152  x 204 (3.8 x 6 x 8)

    Weight

    0.77 kg (1.7 lb)

  • Operating Conditions

    Temperature

    15 to 35°C (59 to 95°F)

    Relative Humidity

    5 to 85% relative humidity, non-condensing

    Altitude

    To 2000 m (6561.68 ft)

  • Typical Applications

    • Semiconductor
    • LCD
    • Electronic assembly