Contact Sensor Type Vibration Monitoring System (VM-9301 series)

Thương hiệu : IMV

Cam kết và Chính sách của TECHNO

  • icon

    Cam kết 100% Hàng chính hãng

  • icon

    Chất lượng cao, đáp ứng đa dạng nhu cầu

  • icon

    Tư vấn kỹ thuật toàn diện và chuyên sâu

  • icon

    Chính sách bảo hành và hỗ trợ nhanh chóng

Permanent vibration monitoring for systems such as motor, pump and blower.

Monitoring system suitable for multi-channel measurement. Frequency range, measurement range or output signal can be customized.

Features

Compatible with conventional systems

A wide range of compatible sensors

Selectable from electrodynamic velocity sensor or piezoelectric sensor.

Electrodynamic velocity sensors

Specialized in medium frequency (up to 1,000 Hz) vibration detection. Suitable to velocity monitoring.

Model VP-3144C/D VP-3354 A
(Horizontal only)
VP-3364 A
(Vertical only)
VP-3134AEX VP-3213 AC/AD VP-3133 HEX/VEX
Sensitivity 10 mV/(mm/s) 10 mV/(mm/s) 10 mV/(mm/s) 17.5 mV/(mm/s) 17.5 mV/(mm/s)
Natural frequency 14 Hz 14 Hz 14 Hz 4.5 Hz 4.5 Hz
Operating temperature range -20 to +80℃ -20 to +80℃ -20 to +70℃ -20 to +70℃ -20 to +70℃
Structure Drip-proof (Equivalent to IP32) Water-proof (Equivalent to IP66) Flame-proof (EX d ⅡBT4Gb) Drip-proof (Equivalent to IP32) Flame-proof (EX d ⅡBT4Gb)
Outward appearance VP-3144 C/D

Type C

VP-3354 A VP-3364 A VP-3134AEX VP-3213 AC/AD

Type AC

VP-3133HEX,VP-3133VEX
Notes High sensitivity /medium frequency Medium frequency /2-directional Medium frequency /3-directional Medium frequency Low frequency /horizontal only Low frequency /
HEX (horizontal only),
VEX (vertical only)

Other sensors for high temperature or waterproof are also available. Please contact .

Piezoelectric sensors

Specialized in high frequency (over 1,000 Hz) vibration detection. Suitable to acceleration monitoring.

Model VP-A52IW HS-100I
Sensitivity 5 mV/(m/s2) 50 mV/G
Natural frequency 35 kHz 24 kHz
Operating temperature range -30 to +110℃ -20 to +80℃
Structure Insulative and water proof Safe and explosion proof
(Ex iaⅡC T4 Ga)
Outward appearance VP-A52IW VP-HS-100I
Notes Insulated Insulated

Multi-channel

Maximum 12 channel per 1 system is available. Range and function can be set individually per every channel.

Application Example

Cables are laid out between sensors located on a large sized motor of home power generator and a monitoring system housed in a control panel. Monitoring systems can monitor vibration values and output the alarm in an emergency.

Outline Drawing

Unit: mm

A B C D E F G H I
Channel Type 1 channel 90 170 300 88 132 90 148 162 50
Type 3 channel 210 149 300 160 132 180 143 100 195
Type 6 channel 300 149 300 250 132 270 143 100 285
Type 9 channel 390 149 300 340 132 360 143 100 375
Type 12 channel 480 149 300 430 132 450 143 100 465