• Permits extension of the AC and DC current ranges of almost any Digital Multimeters (DMMs) without breaking the circuit under test.
• Using KEW 8115 with KEW 1051/1052 (DMM) the display can be set for direct reading in A.
Measuring range | AC 0.1 – 130Arms (185Apeak) | DC 0 – ±180A |
---|---|---|
Output voltage | AC 10mV/A | DC 10mV/A |
Accuracy | ±1.2%rdg±0.4mV (50/60Hz) ±2.5%rdg±0.4mV (40 – 1kHz) |
±1.2%rdg±0.4mV (*) |
Low battery warning | 2.2V±0.2V or less – Red LED flash (1.9V±0.2V – Automatically power off) |
|
Conductor size | Max. Ø12mm | |
Withstand voltage | AC 3540V (RMS 50/60Hz) for 5 sec. | |
Operating temperature & humidity range | -10 to 55ºC, relative humidity 85% or less (no condensation) | |
Output impedance | Approx. 10Ω or less | |
Applicable standards | IEC 61010-1 CAT III 300V Pollution degree 2, IEC 61010-2-032, IEC 61326-1 |
|
Power source | DC3V (size AAA alkaline battery LR03×2pcs) * Continuous use: approx. 40 hours (Auto power off: approx. 20 minutes) |
|
Cord length | Approx. 1,200mm | |
Output connector | Φ4mm banana plug | |
Dimensions | 127(L)×42(W)×22(D) mm | |
Weight | Approx. 140g | |