Charged Plate Monitor That Offers Better Accuracy, Stability, and Bandwidth Than Conventional Designs
The Trek 157 combines patented precision charge measurement capability with features that drive down ionizer maintenance and performance testing costs.
- Monitored Voltage Range: 0 to ±1020 VDC or peak AC
- Bandwidth: (-3dB): DC to 80 Hz
- Decay Mode Thresholds: Programmable from 1 to ±1000 V in 1V increments (accurate within ±1V of programmed voltage)
Overview
The Trek® 157 combines patented precision charge measurement capability with features that drive down ionizer maintenance and performance testing costs. Enhanced features, such as those that enable the operator to store and retrieve data as data points or graphs and record operator comments for reference, make the Trek 157 ideal for use in dissipative testing of materials and monitoring of static charge.
Benefits
- Set custom measurement capacitance for assurance that ESD process needs are met in manufacturing
- Easily transport within a facility with the compact and lightweight design
- Use for ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive, and LCD
Features
- Greater bandwidth enables “true” responses to be observed by avoiding the masking of results
- Extremely low offset and drift ensures high accuracy, making it ideal for applications requiring critical ion balance such as GMR and TMR manufacturing areas
- NIST-traceable Certificate of Calibration provided with each unit
-
Performance
Monitored Voltage Range
0 to ±1020 VDC or peak AC
Bandwidth
DC to 80 Hz (-3dB)
Plate Self-Discharge Rate
Less than 12 V/min
-
Voltage Monitor
Output
BNC provides low voltage replica of plate
Scale Factor
1/200th of the plate voltage
DC Accuracy
Better than 0.1% of full scale
-
Mechanical
H x W x D
102 x 254 x 241 mm (4 x 10 x 9.5 in)
Weight
2 kg (4.4 lb)
Temperature
5 to 35°C (41 to 95°F)
Relative Humidity
To 80% RH, noncondensing
-
Typical Applications
- ESD monitoring of sensitive manufacturing processes such as semiconductor, disk
drive and LCD - Testing of all types of ionizers, including room ionization systems, AC and DC
blowers, nuclear ionizers, gun type ionizers, and pulsed DC ionizers - High temperature applications
- ESD measurement of de-ionized water
- Dissipative testing applications
- ESD monitoring of sensitive manufacturing processes such as semiconductor, disk