Enhanced system performance extends test capabilitiesVibration tests have become diversified and specifications have become increasingly strict.
i-series offer a user-friendly lineup with enhanced performance and durability.
Features
- ■ Expanded test range: maximum values that the i-series can offer
- ・Maximum acceleration: 1250m/s2 ・Maximum velocity: 2.2m/s ・Maximum displacement: 51mmp-p
・Maximum loading mass: 1,000kg - ■ Patented upper (armature) support system PS Guide
- Parallel Slope Guide is standard
- ■ Low noise
- Optimised design of the air intake based on fluid dynamics has reduced the air-intake noise.
- ■ One of the world’s largest class air-cooled systems
- Optimised magnetic circuits based on finite element analysis, and unique cooling technologies have enabled an excitation force of 65kN with air cooling.
- ■ All models can be directly coupled to a climatic chamber.
Table Insert Pattern
Unit: mm
Specification
Standard
System Model | Unit | i210/SA1HAG | i220/SA1HAG | |||
System Specifications | Frequency Range | Hz | 0-4000 | 0-3300 | ||
Rated Force | Sine | kN | 3 | 8 | ||
Random | kN rms | 3 | 8 | |||
Shock | kN | 9 | 16 | |||
Maximum Acc. | Sine | m/s² | 1000 | 1250 | ||
Random | m/s² rms | 700 | 875 | |||
Shock | m/s² peak | 2000 | 2000 | |||
Maximum Vel. | Sine | m/s | 2.2 | 2.2 | ||
Shock | m/s peak | 2.2 | 2.2 | |||
Maximum Disp. | Sine | mmp-p | 30 | 51 | ||
Maximum Travel | mmp-p | 40 | 60 | |||
Maximum Load | kg | 120 | 200 | |||
Power Requirements | kVA | 6.8 | 16.4 | |||
Breaker Capacity | A | 30 | 60 | |||
Vibration Generator | Model | i210 | i220 | |||
Armature Mass | kg | 3 | 6.4 | |||
Armature Diameter | φmm | 128 | 190 | |||
Allowable Eccentric Moment | N・m | 160 | 294 | |||
Dimensions | Width | mm | 868 | 1020 | ||
Height | mm | 700 | 903 | |||
Depth | mm | 458 | 550 | |||
Shaker Body Diameter | φmm | 458 | 550 | |||
Mass | kg | 350 | 900 | |||
Power Amplifier | Model | SA1HAG-i10 | SA1HAG-i20 | |||
Maximum Output | kVA | 5 | 10 | |||
Dimensions | Width | mm | 580 | 580 | ||
Height | mm | 1750 | 1750 | |||
Depth | mm | 850 | 850 | |||
Mass | kg | 240 | 280 | |||
Controller | Vibration Controller | See Vibration Controller K2 | ||||
Cooling | Cooling Method | Air cooling | ||||
Blower | Dimensions | Width | mm | 386 | 492 | |
Height | mm | 882 | 1128 | |||
Depth | mm | 369 | 625 | |||
Mass | kg | 22 | 70 | |||
Wattage | kw | 0.4 | 1.5 | |||
Duct Hose Diameter | φ | 125 | 125 |
*Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
*Power supply: 3-phase 200/220/380/400/415 V (A74 is only AC380/400/415 V), 50/60 Hz. A transformer is required for other supply voltages. |
*Breaker capacity for AC 200 V. |
*Specification above applies to 60 Hz. Dimensions change for 50 Hz. |
*The specification shows the maximum system performance. For long-duration tests, system must be de-rated up to 70%.Continuous use at maximum levels may cause failure. Please contact IMV if your system operates at more than 70%. |
*For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
*Frequency range values vary according to the sensor andvibration controller. |
*Armature mass and acceleration may change when a chamber is added. |
*Mass and dimensions may change for CE-marked systems. |
ECO
System Model | Unit | i220/EM1HAG | |||
System Speciafications | Frequency Range | Hz | 0-3300 | ||
Rated Force | Sine | kN | 8 | ||
Random | kN rms | 8 | |||
Shock | kN | 16 | |||
High Velocity Shock | kN | 10 | |||
Maximum Acc. | Sine | m/s² | 1250 | ||
Random | m/s² rms | 875 | |||
Shock | m/s² peak | 2000 | |||
High Velocity Shock | m/s² peak | 1562 | |||
Maximum Vel. | Sine | m/s | 2.2 | ||
Shock | m/s peak | 2.2 | |||
High Velocity Shock | m/s peak | 3.5 | |||
Maximum Dsp. | Sine | mmp-p | 51 | ||
High Velocity Shock | mmp-p | 51 | |||
Maximum Travel | mmp-p | 60 | |||
Maximum Load | kg | 200 | |||
Power Requirements | kVA | 16.4 | |||
Breaker Capacity | A | 60 | |||
Vibration Generator | Model | i220 | |||
Armature Mass | kg | 6.4 | |||
Armature Diameter | φmm | 190 | |||
Allowable Eccentric Moment | N・m | 294 | |||
Dimensions | Width | mm | 1020 | ||
Height | mm | 903 | |||
Depth | mm | 550 | |||
Shaker Body Diameter | φmm | 550 | |||
Mass | kg | 900 | |||
Power Amplifier | Model | EM1HAG-i20 | |||
Maximum Output | kVA | 10 | |||
Dimensions | Width | mm | 580 | ||
Height | mm | 1750 | |||
Depth | mm | 850 | |||
Mass | kg | 330 | |||
Controller | Vibration Controller | See Vibration Controller K2 | |||
Cooling | Cooling Method | Air cooling | |||
Blower | Dimensions | Width | mm | 492 | |
Height | mm | 1128 | |||
Depth | mm | 625 | |||
Mass | kg | 70 | |||
Wattage | kw | 1.5 | |||
Duct Hose Diameter | φ | 125 |
*Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
*Power supply: 3-phase 200/220/380/400/415 V (A74 is only AC380/400/415 V), 50/60 Hz. A transformer is required for other supply voltages. |
*Breaker capacity for AC 200 V. |
*Specification above applies to 60 Hz. Dimensions change for 50 Hz. |
*For high velocity option |
*The specification shows the maximum system performance. For long-duration tests, system must be de-rated up to 70%. |
*Continuous use at maximum levels may cause failure. Please contact IMV if your system operates at more than 70%. |
*For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
*Frequency range values vary according to the sensor and vibration controller. |
* Armature mass and acceleration may change when a chamber is added. |
*Mass and dimensions may change for CE-marked systems. |
US:ECO
System Model | Unit | i220/EM1HAG | |||
System Specifications | Frequency Range | Hz | 0-3300 | ||
Rated Force | Sine | lbf | 1800 | ||
Random | lbf rms | 1800 | |||
Shock | lbf | 3600 | |||
High Velocity Shock | lbf | 2250 | |||
Maximum Acc. | Sine | g | 127 | ||
Random | g rms | 89 | |||
Shock | g peak | 204 | |||
High Velocity Shock | g peak | 159 | |||
Maximum Vel. | Sine | in/s | 87 | ||
Shock | in/s peak | 87 | |||
High Velocity Shock | in/s peak | 137 | |||
Maximum Dsp. | Sine | inp-p | 2.0 | ||
High Velocity Shock | inp-p | 2.0 | |||
Maximum Travel | inp-p | 2.4 | |||
Maximum Load | lbs | 440 | |||
Power Requirements | kVA | 16.4 | |||
Breaker Capacity | A | 30 | |||
Vibration Generator | Model | i220 | |||
Armature Mass | lbs | 14.1 | |||
Armature Diameter | φin | 7.5 | |||
Allowable Eccentric Moment | lbf in | 2600 | |||
Dimensions | Width | in | 40 | ||
Height | in | 36 | |||
Depth | in | 22 | |||
Shaker Body Diameter | φin | 22 | |||
Mass | lbs | 1984 | |||
Power Amplifier | Model | EM1HAG-i20 | |||
Maximum Output | kVA | 10 | |||
Amplifier Bay (s) | 1 | ||||
Dimensions | Width | in | 23 | ||
Height | in | 69 | |||
Depth | in | 33 | |||
Mass | lbs | 728 | |||
Controller | Vibration Controller | See Vibration Controller K2 | |||
Cooling | Cooling Method | Air cooling | |||
Blower | Dimensions | Width | in | 20 | |
Height | in | 45 | |||
Depth | in | 25 | |||
Mass | lbs | 155 | |||
Wattage | kw | 1.5 | |||
Duct Hose Diameter | φ | 125 |
* Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements. |
* Power supply: 3-phase 220/480V, 60Hz. A transformer is required for other supply voltages. |
* Breaker capacity for 480V. |
* Specification above applies to 60 Hz. Dimensions change for 50 Hz. |
* For high-velocity option. |
* For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock. |
* Frequency range values vary according to sensor and vibration controller. |
* Armature mass and acceleration may change when a chamber is added. |
* Mass and dimensions may change for CE-marked systems. |