Overview
- Feeling (load-angle) test of on-board lever switches.
- Waveform data shown on a PC in real time.
- Switch ON-OFF point detection; 8 points max.
- Any of non-voltage contact measurement, contact voltage drop point measurement and resistance measurement selectable.
Specifications
MODEL-1910/3 | |
Main unit and controller specifications | |
Max. load | 200N |
Test speed | 6~600 mm/min. variable |
Move speed | Low, middle, high |
Load detection method | Load cell Model 3020S |
Load display resolution | 200.00N |
Measuring load accuracy | ±0.2%F.S. |
Angle detection method | Motor pulse |
Max. measuring range | ± 90.0 deg |
Distance measurement accuracy | Within ±0.1 deg |
Contact ON-OFF point detection | 8 contacts, non-voltage or voltage drop point |
Contact resistance measurement | Voltage drop measurement |
Control | PLC |
Tester – PC communication | Ethernet |
Dimensions | W600 x D700 x H2052 mm |
Mass | Approx. 240 Kg |
Power supply | 100VAC/200VAC ±10% |
Jig/fixture (Optional) | |
Manual X-Y stage | Manual X-Y stage±100mm |
Manual tilt-horizontal rotary stage | Tilt ±90 deg, rotation 360 deg |
Standard set | Tester Load cell Model 3020S Dedicated software |
Options | Personal computer Manual X-Y stage Manual tilt-horizontal rotary stage |