Signal Converter (VM-5011A)
Application |
Measuring System |
---|---|
Brand |
IMV |
Sub Categories |
Reliability & Durability Test and Measurements |
Category: Test and Measurements
Description
Specification
Standard
Item | Specification | |
Input range | 0 to 500m/s² | |
Measuring range of frequency | E accerelation | 10 Hz to 1 kHz Band pass filter:500 Hz to 10 kHz See instruction manual "10-2. Standard Characteristic of Converter" |
Velocity | 10 Hz to 1 kHz (ISO 2954:2012 Filter characteristics compliant) See instruction manual "10-2. Standard Characteristic of Converter" | |
Measuring range* | E accerelation | □ 10 m/s²E rms □ 25 m/²E rms ■ 50 m/²E rms □ 100 m/²E rms |
Velocity | □ 10 mm/s rms □ 25 mm/s rms ■ 50 mm/s rms □ 100 mm/s rms | |
Connect sensor* | ■ VP-100 □ VP-8021A | |
DC output* | E accerelation | ■ 4-20 mA (Load 500 Ω or lower) □ 0-10 V (Load 100 kΩ or higher) |
Velocity | ■ 4-20 mA (Load 500 Ω or lower) □ 0-10 V (Load 100 kΩ or higher) | |
AC output | E accerelation | 0-1 Vrms (Load 100 kΩ or higher) |
Velocity | 0-1 Vrms (Load 100 kΩ or higher) | |
Linearity | DC output | Within ±3%F.S |
AC output | Within ±5% | |
Sensor waveform output | Depends on sensor voltage sensivitity Vias voltage: 9 VDC | |
Operating temperature/humidity range | 0 to 50℃、95%RH or less (without freezing or condensing) | |
Suitable cable of terminal block | 0.2 to 2.5mm² (single wire/standard wire) (AWG12 to 24) | |
Power supply of converter | DC24 V ±10% | |
Power supply of sensor | DC24 V 3.5 mA ±20% | |
Power comsumption | 3W or less | |
Case material | Resin | |
Size | 22.6 (W) x 99 (H) x113.6 (D) mm (Excluding protrusions) | |
Mass | Approx.150 g |
* ■ means factory default setting