IET Labs, Inc

SCR-5156-IET ELECTROMETER CALIBRATION STANDARD

Brand

IET Labs, Inc

Sub Categories

Lab tools

Application

Standard Resistor

Category: Test and Measurements
Share:
close
YOU MAY ALSO LIKE…
  • FM-2031 Nitrogen Heavy Duty Soldering System Kit
  • PRESTO 981 Gun-Style Soldering Iron
  • Hakko BLUE 508 Soldering Iron
  • Soldering System with Air Control Unit
  • GENERAL
  • DESCRIPTION
  • SPECIFICATION
  • DATASHEET AND MANUAL
  • ACCESSORIES
GENERAL

GENERAL

  • 4 resistance standards 100 MΩ to 100 GΩ
  • 1 nF and 100 nF capacitors for charge calibration
  • Accuracy: 1%
  • Accredited calibration certificate
  • Excellent replacement for Keithley 5156
  • For use with the Keithley 6517 and other electrometers
  • Custom resistance values are available upon request
DESCRIPTION

DESCRIPTION

High-performance, electrometer calibration standard for use with the Keithley 6517 and other electrometers.

The SCR-5156-IET contains 4 resistors and 2 capacitors, with appropriate uncertainties, as recommended in the Keithley 6517 Service Manual for current and coulombs verification.

Below is the equipment required for verification from the Keithley 6517B Manual.

Equipment needed for verification

    • Fluke 5700A calibrator with user documentation
    • Keithley Model 2002 Digital Multimeter
    • Thermocouple calibrator

Precision resistors with a value known to the listed uncertainty:

      • 100 GΩ, 850 ppm
      • 10 GΩ, 550 ppm
      • 1 GΩ, 550 ppm
      • 100 MΩ, 250 ppm

    Uncalibrated precision resistors:

 

    • 10 MΩ
    • 1 MΩ
    • 10 KΩ
    • 1 KΩ
    • 10 Ω
    • 1 Ω

Precision capacitors with a value known to the listed uncertainty:

  • 1 nF, 1000 ppm
  • 100 nF, 1000 ppm
  • Triaxial shielding cap

The Keithley Certificate of Calibration also uses a 1 TΩ and 10 TΩ precision resistors which are available from IET in the SRC product line of high resistance standards.

The metal housing provides shielding from noise and a shorting link is provided to connect guard and ground when required.

The output of the SCR-5156-IET is a triaxial connector for direct connection to the Keithley 6517.

There are 6 bnc connectors for each of the internal standards.

The calibrated value of each standard is located on the front panel.

Custom resistance values are available upon request

SPECIFICATION

SPECIFICATION

BASIC SPECIFICATIONS

(See datasheet for full specifications)

Calibrated Values: 23°C; traceable to SI with measurement uncertainties, capacitance is calibrated at 1 kHz, 15 Vac
Maximum Input Voltage: 500 Vpk

 

Nominal

Value

Initial adjustment to nominal Stability 1 year (ppm) Tempco (ppm/°C) Voltage Coefficient

(ppm/V)

Material Type
100 MΩ 1% 100 35 1 Thick-film
1 GΩ 100 35 1
10 GΩ 500 50 2
100 GΩ 5
1 nF 5 Polystyrene
100 nF 5 MPP
Terminals:6 bnc connectors for standard values One triaxial output which is common for all 6 standards One five-way binding post for guard with shorting link for connection to ground, and one ground post electrically connected to case
Temperature: Operating 23°C ± 3°C
Humidity: 30 to 60 % RH non-condensing
Dimensions: 20 cm W x 11 cm H x 5.7 cm D (7.55″ W x 4.38″ H x 2.24″ D)
Weight: 2.4 kg (3.5 lbs), nominal
DATASHEET AND MANUAL

DATASHEET AND MANUAL

  • Data Sheet: This document explains the features, options, Specifications and option models for this item.
  • Product Manual: Specifications and option models for this item. This document contains the technical product manual and guidelines.
ACCESSORIES

ACCESSORIES

ISO-17025 Accredited Calibration with Test Data

ISO-17025 ACCREDITED CALIBRATION WITH TEST DATA

Related products

Data Acquisition Analysis System Wave Stocker (VM-0330/16)

K-Series (High Excitation Force Water Cooled Range)

K2

DC-Series (2-Axis Changeover System)

CardVibro Air2 (VM-2012/VM-2012C)

No.316 RING CRUSH TESTER

Seismic Monitoring System (SW-72R)

I-Series (Standard Range)

CONTACT US

Hanoi Office:
Address: 5th Floor, 84 Duy Tan Street, Cau Giay District., Hanoi, Vietnam
Tel: +84 (24) 3795 9933
Fax: +84 (24) 3795 9944
Hotline: 0907910088
Email: Sales@technovietnam.com

HCM Office:
Address: No. 54, Street 6, Trung Son Area (KDC Trung Sơn), Binh Hung, Binh Chanh District, HCM
Tel: +84 (28) 5431 6377
Fax: +84 (28) 5431 6378
Hotline: 0907910088
Email: Sales@technovietnam.com

MAIN MENU

  • Home
  • About Us
  • Products
  • Partners
  • Services
  • News
  • Recruit
  • Contact Us

PRODUCT CATEGORIES

  • Reliability & Durability Test and Measurement
  • Electric & Electronic Test and Measurements
  • Industrial Machines & Automation System
  • Material Inspection and Analysis
  • Optical & Mechanical Test and Measurements
  • Other Test and Measuring Instruments
  • Parts Accessories & Consumables
  • Tools - Handtools - Industrial Tools
COPYRIGHT 2015 TECHNO VIETNAM. ALL RIGHTS RESERVED.
payments
Close
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Shopping cart
close

Sign in

close

Lost your password?

No account yet?

Create an Account
Sidebar
Start typing to see products you are looking for.
x
x
Home
Shop
Blog
Menu