GENERAL
|
|
Brand | IET Labs, Inc |
---|---|
Sub Categories | Lab tools |
Application | Standard Resistor |
|
|
The SRX and SRC Series are cost effective, stable, laboratory or portable resistance standards.
Their ruggedness and small size plus their low temperature coefficient makes the SRX and Series Resistance Standard ideal for any applications outside of laboratory environment within the temperature range of 18°C to 28°C.
Because of the low temperature coefficient, they require no oil-or-temperature bath. The resistor elements are hermetically sealed to minimize affects of humidity.
The 5-way binding posts are gold plated and constructed of low-thermal emf material. Four binding posts are used for resistance values of 190 kΩ and under; two binding posts and Kel-F washers are used for 1 MΩ and over.
For lower resistances, the SRX series resistance standards are available in values ranging from 1 mΩ to 100 MΩ, with custom values available.
For higher resistances, the SRC series resistance standards are available in values ranging from 190 MΩ to 10 TΩ, with custom values available.
It is possible to maintain the SRX & SRC resistance standards indefinitely. They are reliable due to their closed, rugged design and sealed resistors. The units are resistant to electromagnetic interference (EMI) because of their metal enclosure.
SRX/SRC High Resistance Standard Basic Specifications
Model | Nominal Value (Ω) | Adjustment to Nominal (ppm) | Calibration Uncertainty (ppm) | Stability 1 year (ppm) | Tempco (ppm/°C) | Power Coef.(ppm/mW) |
SRX-0.001 | 0.001 Ω | 200 | 200 | 50 | 20 | 0.1 |
SRX-0.0019 | 0.0019 Ω | 200 | 200 | 50 | 20 | 0.1 |
SRX-0.002 | 0.002 Ω | 200 | 200 | 50 | 20 | 0.1 |
SRX-0.01 | 0.01 Ω | 200 | 100 | 50 | 20 | 0.1 |
SRX-0.019 | 0.019 Ω | 200 | 100 | 50 | 20 | 0.1 |
SRX-0.1 | 0.1 Ω | 200 | 20 | 50 | 20 | 0.1 |
SRX-0.19 | 0.19 Ω | 200 | 20 | 50 | 20 | 0.1 |
SRX-1 | 1 Ω | 20 | 10 | 20 | 10 | 0.5 |
SRX-1.9 | 1.9 Ω | 20 | 10 | 20 | 10 | 0.5 |
SRX-10 | 10 Ω | 10 | 5 | 10 | 3 | 0.15 |
SRX-19 | 19 Ω | 10 | 5 | 10 | 3 | 0.15 |
SRX-50 | 50 Ω | 10 | 5 | 10 | 1 | 0.05 |
SRX-100 | 100 Ω | 10 | 5 | 10 | 1 | 0.05 |
SRX-190 | 190 Ω | 10 | 5 | 10 | 1 | 0.05 |
SRX-1K | 1 kΩΩ | 10 | 2 | 10 | 1 | 0.05 |
SRX-1.9K | 1.9 kΩ | 10 | 2 | 10 | 1 | 0.05 |
SRX-10K | 10 kΩ | 10 | 2 | 10 | 1 | 0.05 |
SRX-19K | 19 kΩ | 10 | 2 | 10 | 1 | 0.05 |
SRX-100K | 100 kΩ | 10 | 2 | 10 | 1 | 0.05 |
SRX-190K | 190 kΩ | 10 | 2 | 10 | 1 | 0.05 |
SRX-1M | 1 MΩ | 20 | 5 | 15 | 3 | 0.15 |
SRX-1.9M | 1.9 MΩ | 20 | 5 | 15 | 3 | 0.15 |
SRX-10M | 10 MΩ | 20 | 10 | 20 | 5 | 0.25 |
SRX-19M | 19 MΩ | 20 | 10 | 20 | 5 | 0.7 |
SRX-100M | 100 MΩ | 50 | 15 | 20 | 5 | 1.2 |
SRC-190M | 190 MΩ | 0.10% | 30 | 500 | 25 | |
SRC-1G | 1 GΩ | 0.50% | 100 | 100 | 50 | |
SRC-1.9G | 1.9 GΩ | 0.50% | 100 |
500 |
50 | |
SRC-10G | 10 GΩ | 0.50% | 200 | 50 | ||
SRC-19G | 19 GΩ | 0.50% | 500 | 50 | ||
SRC-100G | 100 GΩ | 0.50% | 900 | 50 | ||
SRC-190G | 190 GΩ | 1% | 900 | 50 | ||
SRC-1T | 1 T | 2% | 2500 | 100 | ||
SRC-1.9T | 1.9 T | 2% | 2500 | 1000 | 200 |
SRC-TN T-Network High Resistance Standard Basic Specifications
Model | Nominal Value (Ω) | Adjustment to Nominal (ppm) | Calibration Uncertainty (ppm) | Stability 1 year (ppm) | Tempco (ppm/°C) | Voltage Coef.(ppm/V) |
SRC-10T-TN | 10 TΩ | 1% | 750 | 500 Typically 100 ppm after first year |
25 | 1 |
SRC-20T-TN | 20 TΩ | |||||
SRC-50T-TN | 50 TΩ | |||||
SRC-100T -TN | 100 T |
SRC Series Maximum Voltage: 5000 V.
Test Conditions: Four-terminal Kelvin measurements, low power, at 23°C; two-terminal for 1 MΩ and over. Initial calibration data traceable to NIST is provided.
Terminals: SRX: Four 5-way binding posts for 4-terminal measurement for 190 kΩ and under; two binding posts for 1 MΩ and over. The binding posts are constructed of tellurium copper for low thermal emf and low resistance. A case ground terminal is also provided. Triax and bnc terminals are also available.
SRC: Additional GUARD terminal is provided.
Dimensions: 8.6 cm H x 10.5 cm W x 12.7 cm D (3.4″ x 4.15″ x 5″).
Transit Case: Optional Model SRC-100 light weight transit case with handle, suitable for transporting and storing two units. The case provides mechanical protection and insulation from temperature changes during transportation or shipping.
Operating Temperature Range: 15 to 30°C.
Test and Measurements
Test and Measurements
Test and Measurements
Test and Measurements
Test and Measurements
Test and Measurements
Test and Measurements
Test and Measurements