The E10 Series is a DIN 72 x 72 preset counter with a single level. The display is a 6 digits Red LED with a figure size of 10.16 x 5.54mm. The E10 Series is a very reliable preset counter which accepts Contact or Open Collector input signal and can count Add or Subtract or Quadrature (bidirectional) at count speeds up to 10kHz. The counter has a built-in relay that will actuate once preset level is reached. Preset values are set via the front panel digital switches. The unit is powered by selectable 100/110 or 200/220VAC.
Display | 6 Digits 7-Segment Red LED 10.16 mm (H) x 5.54 mm (W) |
Power Source | 100/110 VAC or 200/220 VAC, 50/60 Hz |
Power Consumption | 4.3 VA |
Preset Level | 1 Level |
Setting Range | 0 – 999999 * |
Input Mode | Open Collector Input L : 0 to 2 V (sink current 7mA max.) Contact Input: Relay, Microswitch, etc. (sink current 7mA max.) |
Count Mode | 90°Quadrature Input / Individual Add/Subtract Input (simultaneous input of add and subtract is not possible) |
Count Speed | Open Collector Input: 10kHz / Contact Input: 30Hz |
Pulse Width | Open Collector Input:50µs / Contact Input: 16.6ms |
Duty | 1 : 1 |
Output | Relay Type 1C, 250 VAC, 2A (125VA), 220 VDC 2A (60W) cosФ = 1 |
Output Display | Red LED (ON when output is actuated) |
Output Time | 0.1 to 1second per shot (adjustable via front panel knob) or latch output |
Reset Input | Contact (100 ms min.) Open Collector (sink current 10mA max.) |
Reset Mode | Remote Reset, Auto-Reset, Front Panel Reset (E10-166MR) |
Operation Mode | Auto-reset (display resets when preset value is reached) Overrun (counting continues even after preset value is reached) |
Memory | E²PROM Data Retention: approximately 20 years Memory Frequency: 100,000 times max. |
Power Source for Sensor | 12 VDC, 60mA max. |
Operating Temperature | -10 to +50°C (should not be frozen) |
Operating Humidity | 35 to 85 % RH (non-condensing) |
Hi-pot Test | 1500 VAC (1minute) |
Insulation Resistance | 100 MΩmin. (500 VDC Megger) (on Power leads and between non-charged metal parts) |
Noise Immunity | Square wave noise from Noise Simulator ±2.0kV (PowerTerminals),±500V(Input Terminals) |
Vibration Immunity | Malfunction: 10 to 55 Hz, double amplitude 0.5mm Destruction: 16.7 Hz, double amplitude 4mm |
Shock Immunity | Malfunction: 100 m/s²(10G) Destruction: 300 m/s²(30G) |
Weight | 550g |