• English
    • Deutsch
    • French
    • Requires WPML plugin
  • Country
    • United States (USD)
    • Deutschland (EUR)
    • Japan (JPY)
FREE SHIPPING FOR ALL ORDERS OF $150
0 items / $0.00
Login / Register
  • Newsletter
  • Contact Us
  • FAQs
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Vietnamese
Menu
Home Industrial Machines & Automation System Non-freon chillers – PCU-NE6000W
Non-freon chillers - PCU-NE2500W
Back to products
High-performance chillers - PCU-SL10000
Click to enlarge
Apiste

Non-freon chillers – PCU-NE6000W

Brand

Apiste

Application

Chiller

Sub Categories

Industrial cooling, cleaning systems

Category: Industrial Machines & Automation System
Share:
close
YOU MAY ALSO LIKE…
  • FM-2031 Nitrogen Heavy Duty Soldering System Kit
  • PRESTO 981 Gun-Style Soldering Iron
  • Hakko BLUE 508 Soldering Iron
  • Soldering System with Air Control Unit
  • Description
Description

PCU-NE Series non-freon chillers use R1234yf refrigerant. Because the PCU-NE Series chillers uses non-freon refrigerant they are exempt from the Fluorocarbons Recovery and Destruction Law and have absolutely no fluorocarbon-related labor and costs such as periodic inspections and preparing process management documentation required of fluorocarbon chillers. What’s more, they are the first chillers in the industry market with drive recorder and time calendar functions. The chiller records circulation water outlet temperature, circulation water set temperature, accumulated operating time, error date and time, and other important operation data in two minute intervals. By monitoring chiller operation status and isolating the cause of problems, these functions greatly reduce the time and effort consumed on dealing with problems just in case one occurs.

Specifications

(50 / 60Hz)

Cooling schemeWater-cooling type
Cooling capacity (W) *15400 / 6000
Heating capacity (W) *11400 / 1900
Circulated water *2Distilled water, Pure water (1μS/cm or more), Ethylene glycol solution (concentration 15 wt% or less), Propylene glycol solution (concentration 15 wt% or less)
Temperature stability (℃) *3±0.1
Use Area Temperature (℃)5 to 45
Circulating water temperature range (℃)5 to 40
Circulating water rated flow rate (ℓ/min)30/35
Maximum discharge pump head (m) *434/48
Tank capacity (ℓ)Approx. 12
Cooling water / Temperature range (℃)5 to 45
Cooling water / Pressure range (Mpa)0.1 to 0.7
Cooling water / Required flow rate (ℓ/min)15 or more
Cooling water inlet / Outlet diameterRc1/2
Dimensions (mm) *5H997×W400×D600
Coating ColorMunsell N-87
Weight (kg)Approx. 82
Casters (Φmm×unit)50×4
Rated Voltage (V) *63-phase 200 VAC / 200~220
Power Consumption (kW) *11.9 / 2.4
Current consumption (A) *19.4 / 8.6
Recommended breaker capacity (A)30
Circulating water inlet / outlet port sizeRc3/4
Drain discharge port sizeG1/2
Components / CompressorFully sealed rotary type
Components / CondenserStructure : Plate-type heat exchanger
Material : SUS316 (copper brazing)
Components / EvaporatorStructure : Plate-type heat exchanger
Material : SUS316 (copper brazing)
Components / Circulating pumpStructure : Multi-stage centrifugal pump
Output : 0.45/0.74 (kW)
RefrigeratorR1234yf 550g
Noise (dB) *753 / 59
Safety circuit / CompressorThermal protector, Electromagnetic switch
Safety circuit/PumpElectromagnetic switch
Input / Alarm outputNo voltage open-contact (Max. AC250V/1A, DC30V/2A)
Input/Output / Water temperature upper/lower limit outputNo voltage open-contact (Max. AC250V/1A, DC30V/2A)
Input/Output / Operation stop outputNo voltage open-contact (Max. AC250V/1A, DC30V/2A)
Input/Output / Pump outputNo voltage open-contact (Max. AC250V/1A, DC30V/2A)
Input/Output / Emergency stop inputNo-voltage input
Input/Output / Operation stop inputNo-voltage input
Input/Output / Error reset inputNo-voltage input
Input/Output / External temperature sensor *8Pt100
Input/Output / Ethernet10BASE-T/100BASE-TX
Socket(TCP/IP)、MC protocol(UDP/IP)、Modbus TCP
Display / operation methodMonochrome display, key input
Log dataRecorded items:
Date and time, error number, circulation water set temperature, circulation water outlet temperature, external temperature, chiller run/stop, pump/fan/compressor run/stop, pump independent run status, emergency stop command input terminal status, run-stop command input terminal status, error reset command input terminal status, false warning output status, compressor high-pressure pressure, compressor low-pressure pressure, compressor ejection temperature, compressor intake temperature, water empty sensor status, fan control status, coolant operation volume, high-pressure protection control status, low-pressure protection control status, overheating protection control status, freezing protection control status.
Recording period: Approx. 1 year and 6 months
Recording interval *9: 2 minute intervals
Export method: USB memory, Socket communication
FunctionsGraph display, chiller operation status display, error history display, operation time display, calendar, write memo, water temperature error settings, operation timer settings, password settings, key lock, freeze protection operation, log data USB memory write, external temperature sensor input, cascade control

*1. Values at operating use area temperature 25℃, circulating water temperature 20℃, and circulating water rated flow rate.
*2. If you want to maintain the electrical conductivity of circulating water with ion exchange resin, etc., please contact our sales staff.
*3. Based on chiller temperature gauge display values under constant load, cooling water temperature of 25℃, circulation water temperature of 20℃, and circulation water flow at rated volume.
*4. Value calculated based on circulation water flow of 4ℓ/min. To prevent pump breakdown, avoid running the chiller with circulation water flow below 4ℓ/min.
*5. Excluding the protruded part.
*6. Maintain power supply voltage within ±10% of rated voltage.
*7. Values measured with a 1m face, 1m height, and no load stability.
*8. External temperature sensor not included. The user prepares the external temperature sensor.
*9. Errors are recorded in 5 second intervals from approximately 1 minute before.

External dimensions

PCU-NE6000W External dimensions

Related products

Precision Cutters – PetroThin

Cloth Guide System ELTWIN

Grinder Polishers – AutoMet 250

UE.UEC 108.225 (Motor Driven Grease Pump)

Pivoting Frame System Eltrac

Precision Cutters – IsoMet Low Speed

Grinder Polishers – AutoMet 300 Pro

Castable Mounting – SimpliVac

CONTACT US

Hanoi Office:
Address: 5th Floor, 84 Duy Tan Street, Cau Giay District., Hanoi, Vietnam
Tel: +84 (24) 3795 9933
Fax: +84 (24) 3795 9944
Hotline: 0907910088
Email: Sales@technovietnam.com

HCM Office:
Address: No. 54, Street 6, Trung Son Area (KDC Trung Sơn), Binh Hung, Binh Chanh District, HCM
Tel: +84 (28) 5431 6377
Fax: +84 (28) 5431 6378
Hotline: 0907910088
Email: Sales@technovietnam.com

MAIN MENU

  • Home
  • About Us
  • Products
  • Partners
  • Services
  • News
  • Recruit
  • Contact Us

PRODUCT CATEGORIES

  • Reliability & Durability Test and Measurement
  • Electric & Electronic Test and Measurements
  • Industrial Machines & Automation System
  • Material Inspection and Analysis
  • Optical & Mechanical Test and Measurements
  • Other Test and Measuring Instruments
  • Parts Accessories & Consumables
  • Tools - Handtools - Industrial Tools
COPYRIGHT 2015 TECHNO VIETNAM. ALL RIGHTS RESERVED.
payments
Close
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Shopping cart
close

Sign in

close

Lost your password?

No account yet?

Create an Account
Sidebar
Start typing to see products you are looking for.
x
x
Home
Shop
Blog
Menu