• Flexible and light weight clamp sensor
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V /CAT III 1000V)
• True RMS










AC A (RMS) | |||
Range | 4.000/40.00/400.0A | ||
Accuracy | ±3%rdg±5dgt[45-500Hz] | ||
Crest factor | Full scale CF<1.6, half scale<3.2 | ||
Conductor size | Ø70mm max. | ||
Influence of | Additional ±2% (max.) depending on the distance from the center position | ||
Overload protection | 500A AC for 10 seconds | ||
Applicable standards | IEC 61010-1, IEC 61010-2-032 | ||
Operating temperature | 0 - +50℃,less than 80% RH (without condensation) | ||
Storage temperature | -10 - +60℃,less than 70% RH (without condensation) | ||
Power source | R03 / LR03(AAA)(1.5V)×2 | ||
Dimensions | 120(L)×70(W)×26(D):Display unit | ||
Weight | 200g approx. (including batteries) | ||
Included Accessories | 9174 (Carrying case) | ||