• English
    • Deutsch
    • French
    • Requires WPML plugin
  • Country
    • United States (USD)
    • Deutschland (EUR)
    • Japan (JPY)
FREE SHIPPING FOR ALL ORDERS OF $150
0 items / $0.00
Login / Register
  • Newsletter
  • Contact Us
  • FAQs
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Vietnamese
Menu
Home Industrial Machines & Automation System High-performance chillers – PCU-SL14000
AC Digital Clamp Meters MODEL 2031
Back to products
High-performance chillers - PCU-SL12000W
Click to enlarge
Apiste

High-performance chillers – PCU-SL14000

Brand

Apiste

Application

Chiller

Sub Categories

Industrial cooling, cleaning systems

Category: Industrial Machines & Automation System
Share:
close
YOU MAY ALSO LIKE…
  • FM-2031 Nitrogen Heavy Duty Soldering System Kit
  • PRESTO 981 Gun-Style Soldering Iron
  • Hakko BLUE 508 Soldering Iron
  • Soldering System with Air Control Unit
  • Description
Description

The high-performance chiller PCU-SL Series' innovative IOF sensor constantly monitors circulation water inlet and outlet temperature and circulation water flow rate. By making it possible for the chiller to detect changes in load and flow faster and more accurately caused by production processes than any other chiller, the sensor quickly stabilizes circulation water temperature. What's more, PCU-SL Series chillers have an innovative structure that gives them the toughness needed for harsh environments. Additionally, a structure that separates the top and bottom of the unit provides IPX4 water protection that withstands tests even more demanding than JIS standards, thus making it possible to install the chiller outdoors with confidence.

Specifications

(50 / 60Hz)

Cooling schemeAir-cooling type
Cooling capacity (W)13300
Heating capacity (W)2500
Circulated waterPure water (over 1μs/cm), distilled water, ethylene glycol (less than 30% density), top water
Temperature stability (℃)±0.1
Use Area Temperature (℃)-5~45
Water setting temperature range (℃)-5 to 45
Circulated water temperature range (Clear water) (℃)5~45
Circulated water temperature range (Anti-freeze water) (℃)-5~45
Circulated water flow rate range (L/min)20~70
Circulated water pressure range (Mpa)0.7 or less
Circulating pump/Head (m)51m (45L/min / 3600rpm) (max. lift 71m)
Maximum tank capacity (ℓ)35
Cooling water / Temperature range (℃)5~45
Dimensions (mm)H1496×W850×D750
Coating ColorDIC G-260 (Munsell : N7.5 or suitable color)
Weight (kg)145
Rated Voltage (V)3-phase AC200~230V
Power Consumption (kW)5.7
Current consumption (A)17.0
Current Consumption/MIN (A)17.0
Current Consumption /MAX (A)22
Voltage source capacity (kVA)7.6
Recommended breaker capacity (A)30
Components / CompressorShutting tightly Roundabout system
Components / CondenserParallel flow condenser type, forced air cooling system
Components / RefrigeratorPlate-type heat exchanger
Components / Evaporator70
Components / Circulating pumpMultistep spiral dipping mandrel
RefrigeratorR410A 1700g
Noise (dB)73
Safety circuit / CompressorMotor protector
Safety circuit / Refrigeration cyclePressure switch
Safety circuit / Circulating water circuitWater pressure sensor, float switches for water shortage
Input/Output / Alarm outputNo-voltage/normal open (250 VAC/2 A)
Input/Output / Water temperature upper/lower limit outputNo-voltage/normal open (250 VAC/2 A)
Input/Output / Water supply valve/operation outputNo-voltage/normal open (250 VAC/2 A)
Input/Output / Operation stop outputNo-voltage/normal open (250 VAC/2 A)
Input/Output / Pump outputNo-voltage/normal open (250 VAC/2 A)
Input/Output / Emergency stop inputNo-voltage input
Input/Output / Operation stop inputNo-voltage input
Input/Output / Error reset inputNo-voltage input
Input/Output / EthernetCommunication standard: Ethernet 10BASE-T / 100BASE-TX
Communication protocol: Socket (TCP / IP), MC protocol (UDP / IP)
IP address: IPv4
Safety measuresCE (Low-voltage command, EMC command), UL (ETL Certification)
Liquid crystal displaySettings menu: Operation mode/Circulating water temperature alarm/Timer/Various settings/Custom settings/I/O settings/Communication settings/Error history
Circulating water temperature trend: Circulating water temperature upward trend/Downward trend/Stable trend
Graph display: Internal temperature graph, circulating water pressure graph
Input/output monitor: Input 1 (3 points)/Output 1 (3 points)/Output 2 (2 points)
Operation monitor: Compressor high pressure/Compressor low pressure/Circulating water pressure/Circulating water temperature/Compressor discharge temperature/Compressor intake temperature/Circulating water flow rate/Circulating water temperature/Compressor operation time/Fan operation time/Pump operation time

*Cooling capacity, power consumption, current consumption rating: 20 °C circulating water temperature, 45L/min circulation water flow rate, and 32 °C ambient temperature.
*Heating capacity: During start-up operation at an ambient temperature of 40 °C. Varies depending on the ambient temperature.
*Circulated water: Use water with a purity of 1 μS/cm or more (low purity). Pure water: Water quality standards of The Japan Refrigeration and Air Conditioning Industry Association (JRA GL-02-1944)
* Temperature stability: Depends on the display value of the main body temperature indicator at a constant load.
*MAX current consumption: When the circulating water temperature is 20 °C, the circulating water flow rate is 70 L/min, and the ambient temperature is 45 °C.
*Vibration resistance: Up to 100 Hz under the test conditions of the MIL-STD-810F standard.
*Operating noise: Measured at a horizontal distance of 1 m and height of 1 m.

External dimensions

PCU-SL14000 External dimensions

Related products

FB (Manually Operated Grease Pump)

Grinder Polishers – AutoMet 250 Pro

Bridge Web Guider Corraligner

UE.UEC 108.225 (Motor Driven Grease Pump)

Precision Cutters – IsoMet 1000

Precision Cutters – IsoMet Low Speed

UE40 (40 MPa Motor Driven Pump)

Segmented Roller Guider System ELSMART

CONTACT US

Hanoi Office:
Address: 5th Floor, 84 Duy Tan Street, Cau Giay District., Hanoi, Vietnam
Tel: +84 (24) 3795 9933
Fax: +84 (24) 3795 9944
Hotline: 0907910088
Email: Sales@technovietnam.com

HCM Office:
Address: No. 54, Street 6, Trung Son Area (KDC Trung Sơn), Binh Hung, Binh Chanh District, HCM
Tel: +84 (28) 5431 6377
Fax: +84 (28) 5431 6378
Hotline: 0907910088
Email: Sales@technovietnam.com

MAIN MENU

  • Home
  • About Us
  • Products
  • Partners
  • Services
  • News
  • Recruit
  • Contact Us

PRODUCT CATEGORIES

  • Reliability & Durability Test and Measurement
  • Electric & Electronic Test and Measurements
  • Industrial Machines & Automation System
  • Material Inspection and Analysis
  • Optical & Mechanical Test and Measurements
  • Other Test and Measuring Instruments
  • Parts Accessories & Consumables
  • Tools - Handtools - Industrial Tools
COPYRIGHT 2015 TECHNO VIETNAM. ALL RIGHTS RESERVED.
payments
Close
  • Home
  • About us
  • Products
  • Partners
  • Services
  • Customers
  • Recruit
  • Contact us
Shopping cart
close

Sign in

close

Lost your password?

No account yet?

Create an Account
Sidebar
Start typing to see products you are looking for.
x
x
Home
Shop
Blog
Menu