AN Types Series
- Overview
- Applications
Small reduction gears, air blowers/air exhaust ventilators, compressors, driers, machine tools, other small industrial machinery
Specifications
Model | Lubrication amount (L/min) |
Oil pump (L/min x number of units) |
Oil tank (L) |
Electric motor (kw×P) |
Electric heater (kw) |
Lubricating port diameter | Return oil port Flange size |
AN-10 | 10 | 10×1 | 100 | 0.4×4 | 0.3 | Rc ½ | 1½ |
AN-17 | 17 | 17×1 | 200 | 0.75×6 | 0.6 | Rc ¾ | 2 |
AN-30 | 30 | 30×1 | 300 | 0.75×6 | 1.0 | Rc 1 | 2½ |
AN-50 | 50 | 50×1 | 500 | 1.5×6 | 1.5 | Rc 1¼ | 3 |
AN-65 | 65 | 65×1 | 800 | 2.2×6 | 2.5 | Rc 1¼ | 4 |
AN-100 | 100 | 100×1 | 1000 | 3.7×6 | 3.0 | Rc 1½ | 4 |
(Note) Values for a 60 Hz power supply frequency are indicated for lubrication amount and oil pump. When the frequency is 50 Hz, consider these values to drop by 17%.
Common Specifications
Oil used | Oil pump pressure | Oil filtering capacity | Power supply |
Lubricating oil ISO VG 220 |
0.55MPa Safety valve 0.6 MPa |
150mesh | 3-phase 440V/400V 220V/200V 60/50Hz |
BN Type Series
- Overview
This standard model is matched to all kinds of machinery and integrates the most rational combination of component equipment to improve oil filtering capacity and reduce the size of the overall system.
- Applications
Paper making machines, large air blowers/air exhaust ventilators, medium-size reduction gears, iron and steel ancillary facilities (shearing machines, levelers, coilers), other general industrial machinery
Specifications
Model | Lubrication amount (L/min) |
Oil pump (L/min x number of units) |
Oil tank (L) |
Electric motor (kw×P) |
Electric heater (kw) |
Lubricating port diameter |
Return oil port flange size |
Coolant line port diameter |
BN-10 | 10 | 10×2 | 200 | 0.4 ×4 | 0.6 | Rc ½ | 1½ | Rc ½ |
BN-17 | 17 | 17×2 | 500 | 0.75×6 | 1.5 | Rc ¾ | 2 | Rc ¾ |
BN-30 | 30 | 30×2 | 800 | 0.75×6 | 2.5 | Rc 1 | 2½ | Rc 1 |
BN-50 | 50 | 50×2 | 1000 | 1.5 ×6 | 3.0 | Rc 1¼ | 3 | Rc 1¼ |
BN-65 | 65 | 65×2 | 1500 | 2.2 ×6 | 4.0 | Rc 1¼ | 4 | Rc 1¼ |
BN-100 | 100 | 100×2 | 1950 | 3.7 ×6 | 5.0 | Rc 1½ | 4 | Rc 1½ |
(Note) Values for a 60 Hz power supply frequency are indicated for lubrication amount and oil pump. When the frequency is 50 Hz, consider these values to drop by 17%.
Common Specifications
Oil used | Oil pump pressure | Oil filtering capacity | Oil cooling performance | Coolant | Power supply |
Lubricating oil ISO VG 220 |
0.55MPa Safety valve 0.6 MPa |
150mesh | 48℃→40℃ | 32°C or less, 0.2 MPa, industrial water |
3-phase 440V/400V 220V/200V 60/50Hz |
CN Types Series
- Overview
This cellar type is intended for large-scale mechanical equipments.
Systems matched to specific user needs are designed after consultation with the user.
- Applications
Large reduction gears, rolling mills, other large equipment and facilities.