DC4-20mA Output Accelerometer (VP-420/421/422)
Application |
Measuring System |
---|---|
Brand |
IMV |
Sub Categories |
Reliability & Durability Test and Measurements |
Category: Test and Measurements
Description
Specification
Standard
Output type / Model | Velocity (current output) VP-420 | Velocity (current output) + Acceleration waveform (current output) VP-421 | Acceleration (current output) VP-422 |
Frequency range | 10 Hz to 1kHz, ± 5 % (ISO10816) | 10 Hz to 1 kHz, ± 5 % (ISO10816) | 10 Hz to 5 kHz, ± 3 dB |
Measurement range *1 | 10, 20, 25, 50, 100 mm/s rms | 10, 20, 25, 50, 100 mm/s rms | 9.8, 19.6, 49, 98, 980 m/s² rms |
Output sensitivity | 4 to 20 mA / 0 to full scale | 4 to 20 mA / 0 to full scale Acceleration waveform:5 mV / (m/s²) 10.2 mV / (m/s²) | 4 to 20 mA / 0 to full scale |
Voltage supply | DC15 to 30 V, 30 mA or more | ||
Warm-up time | Approx. 2 seconds | ||
Output impedance | DC24 V, maximum 600 Ω | ||
Insulation resistance | DC500 V, 100 MΩ or more | ||
Operating temperature range | -25 to 90 ℃ | ||
Cable length *1 | Standard 5 m (maximum 1,000 m) | ||
Weight | Approx. 150 g (Cable is not included) | ||
Protection structure | Drop-proof direct connection cable type: IP65 (dust-proof, drop-proof) Waterproof connector type : IP67 (dust-proof, waterproof) Water resistant type: IP68 (dust-proof, perfect waterproof: water depth 100 m, 10 bar) |
Please inform us the full scale value. Acceleration output + acceleration waveform output type (VP-423) is also available.