Charge Plate Monitors – Trek 157

Thương hiệu : Trek

Cam kết và Chính sách của TECHNO

  • icon

    Cam kết 100% Hàng chính hãng

  • icon

    Chất lượng cao, đáp ứng đa dạng nhu cầu

  • icon

    Tư vấn kỹ thuật toàn diện và chuyên sâu

  • icon

    Chính sách bảo hành và hỗ trợ nhanh chóng

Charged Plate Monitor That Offers Better Accuracy, Stability, and Bandwidth Than Conventional Designs

The Trek 157 combines patented precision charge measurement capability with features that drive down ionizer maintenance and performance testing costs.

  • Monitored Voltage Range: 0 to ±1020 VDC or peak AC
  • Bandwidth: (-3dB): DC to 80 Hz
  • Decay Mode Thresholds: Programmable from 1 to ±1000 V in 1V increments (accurate within ±1V of programmed voltage)

Overview

The Trek® 157 combines patented precision charge measurement capability with features that drive down ionizer maintenance and performance testing costs. Enhanced features, such as those that enable the operator to store and retrieve data as data points or graphs and record operator comments for reference, make the Trek 157 ideal for use in dissipative testing of materials and monitoring of static charge.

Benefits

  • Set custom measurement capacitance for assurance that ESD process needs are met in manufacturing
  • Easily transport within a facility with the compact and lightweight design
  • Use for ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive, and LCD

 

Features

  • Greater bandwidth enables “true” responses to be observed by avoiding the masking of results
  • Extremely low offset and drift ensures high accuracy, making it ideal for applications requiring critical ion balance such as GMR and TMR manufacturing areas
  • NIST-traceable Certificate of Calibration provided with each unit
  • Performance

    Monitored Voltage Range

     

    0 to ±1020 VDC or peak AC

     

    Bandwidth

     

    DC to 80 Hz (-3dB)

     

    Plate Self-Discharge Rate

     

    Less than 12 V/min

  • Voltage Monitor

    Output

     

    BNC provides low voltage replica of plate

     

    Scale Factor

     

    1/200th of the plate voltage

     

    DC Accuracy

     

    Better than 0.1% of full scale

  • Mechanical

    H x W x D

     

    102 x 254 x 241 mm (4 x 10 x 9.5 in)

     

    Weight

     

    2 kg (4.4 lb)

Temperature

 

5 to 35°C (41 to 95°F)

 

Relative Humidity

 

To 80% RH, noncondensing

  • Typical Applications

    • ESD monitoring of sensitive manufacturing processes such as semiconductor, disk
      drive and LCD
    • Testing of all types of ionizers, including room ionization systems, AC and DC
      blowers, nuclear ionizers, gun type ionizers, and pulsed DC ionizers
    • High temperature applications
    • ESD measurement of de-ionized water
    • Dissipative testing applications