Specifications
Cooling scheme | Water-cooling type |
---|---|
Control models | Temperature control |
Cooling capacity(W) | 7700/8000 |
Thermal capacity(W) | 10400/10700 |
Temperature stability(℃) | ±0.1 |
Use Area Temperature(℃) | 15~35 (Temperature change gradient: Within 1℃/1h) |
Use Area Humidity(%RH) | 15~85 (Humidity change gradient: within 5%RH/1h) (No condensation) |
Processed air volume(m3/min) | 21/24 |
External Dimensions(mm) | H1631×W650×D800 |
Weight(kg) | 220 |
Coating Color | Ivory (Y22-85B semi-gloss) |
Blower duct connection diameter(mm) | φ200 (with damper) |
Rated voltage(V) | Three-phase AC 200 |
Consumption Current(A) | 11(Rated) 15(MAX) |
Consumption wattage(W) | 3500(Rated) 5000(MAX) |
Cooling water / Water supply(ℓ/min) | 30 (Amount of change in water volume: within 1ℓ/1h) |
Cooling water / Water supply pressure(MPa) | 0.2~0.5 |
Cooling water / Supply water temperature(℃) | 5~35 (Change of water temperature: within 1℃/1h) |
Refrigerant(g) | R407C 1600g |
*1 Performance value is taken at a point 4m ahead of the insulation duct. (Ambient temperature and humidity of 25℃ 50%RH , cooling water temperature of 15℃ at 30ℓ/min and air flow of 21/24m3/min)
*2 The temperature and humidity control accuracy is based on the method prescribed in JTMK01 Constant Temperature Humidistat Bath – Performance Testing Method and Performance Display Method (Japan Testing Machine Association). Thermal interference due to ducts etc. is not covered by the precision guarantee. Consider the combined use of insulation ducts etc.
*3 Control may not be possible depending on the ambient temperature and humidity. Discuss the details with our sales representative.
External dimensions
(1) Cooling water outlet
(2) Cooling water inlet
(3) Drain drain port
(4) Overflow drain
Temperature and humidity sensor
[Caution]To ensure proper operation of this equipment, read the operation manual before use.
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
Overseas at the time of delivery, we recommend packing for overseas separately.
After verifying the specifications, insert an appropriate breaker (circuit breaker for wiring) between the product and power supply.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.