Specifications

(50/60Hz)

Mounting type Side-mounting
Cooling capacity(W) 2000/2200
Setting Temperature Range(℃) 25~45
Use Area Temperature(℃) 20~55
Use Area Humidity(%RH) 10~85 (No condensation)
External dimensions(mm) H1200×W450×D260
Weight(kg) 62
Coating Color Munsell 5Y 7/1 Equivalent color of light beige
Rated Voltage(V) Three-phase AC380~415/AC400~460
Consumption Current: Rated(A) 1.7/1.9
Consumption Current: MAX(A) 2.2/2.5
Starting Current(A) 12/13
Consumption wattage: Rated(W) 1000/1200
Consumption wattage: MAX(W) 1350/1700
Noise Resistance LEVEL4 by Fast Transient / Burst Immunity Test
Vibration Resistance Equivalent to JIS Z 0200 Level1
Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route)
Refrigerant / Fill ration(g) R134a 300g
Noise (dB (A)) Approx. 65/67
External Output Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/Error display LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal temperature is 35°C – 40%. (measurement conditions: JIS-C-9612 air enthalpy method))
MAX value: Value at the maximum ambient temperature allowed and an operating ambient humidity of 40%RH.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

Accessories list

Mounting bolt for main unit 6 (M8×L25)
Drain hose 2m
Insulation lock ties 1
Mounting nut 2(M8)
Instruction manual 1

Replacement parts list

Condenser side Fan Circulating fan for ENC-G2240L
Evaporator side Fan Outside air fan for ENC-G2240L
Filter ENC-F-43 (2 pieces)
Control PCB Substrate for ENC-G2240L

Note: Check with our sales representative as the delivery lead time varies depending on the inventory status.
*Note that the model, specifications and other details described are subject to change without notice.

External dimensions

ENC-G2240L External dimensions

Diagram of Panel Cutout

ENC-G2240L Diagram of Panel Cutout

ENC-G2240L
[Standard panel cut (Left)]
*Figure seen from control board outside.
*Please keep screw pace on the occasion of processing.
*Standard panel cut will not be changed even if a model change is carried out (some exceptions apply), but the minimum panel cut dimensions are subject to change without notice.

[Half-embedded Panel Cut (Right)]